Solving the Robot-World/Hand-Eye Calibration Problem Using the Kronecker Product
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This paper constructs a separable closed-form solution to the robot-world/hand-eye calibration problem AX = YB. Qualifications and properties that determine the uniqueness of X and Y as well as error metrics that measure the accuracy of a given X and Y are given. The formulation of the solution involves the Kronecker product and the singular value decomposition. The method is compared with existing solutions on simulated data and real data. It is shown that the Kronecker method that is presented in this paper is a reliable and accurate method for solving the robot-world/hand-eye calibration problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new technique for fully autonomous and efficient 3D robotics hand/eye calibration
Tsai, R. Y., & Lenz, R. K. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34770 · Cited by 1,398
Matrix Analysis for Scientists and Engineers
Laub, A. J. (2004) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898717907 · Cited by 893 · cited 1×
“for matrices A, B, C, and D of appropriate degree [24].”
BackgroundHand-Eye Calibration Using Dual Quaternions
Daniilidis, K. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066213 · Cited by 729
Shiu, Y. C., & Ahmad, S. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.88014 · Cited by 625
Horaud, R., & Dornaika, F. (1995) · The International Journal of Robotics Research · doi:10.1177/027836499501400301 · Cited by 593
Robot sensor calibration: solving AX=XB on the Euclidean group
Park, F. C., & Martin, B. J. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.326576 · Cited by 570 · cited 1×
“Many of these solutions are based on the closed-form solutions of the related hand-eye calibration problem AjX 1⁄4 XBj, which are formulated using either angle-axis formulations for rotations [11–13], Lie group theory [14], quaternions [15–21], screw theory [22], or Kronecker products [23].”
BackgroundStrobl, K., & Hirzinger, G. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.282250 · Cited by 304
Simultaneous robot-world and hand-eye calibration
Dornaika, F., & Horaud, R. (1998) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.704233 · Cited by 298 · cited 4×
“Kronecker method [9] and the Dornaika and Horaud closed-form quaternion method [4] on simulated data.”
MethodInfluentialFinding the Position and Orientation of a Sensor on a Robot Manipulator Using Quaternions
Chou, J. C. K., & Kamel, M. (1991) · The International Journal of Robotics Research · doi:10.1177/027836499101000305 · Cited by 263
Extrinsic calibration of a vision sensor mounted on a robot
Wang, C.-C. (1992) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.134271 · Cited by 173
Cited by
Park, T. H., Bosse, J., & D'Amico, S. (2021) · arXiv · doi:10.48550/arxiv.2108.05529 · Cited by 10
Metadata
- Authors
- Shah, M.
- Venue
- Journal of Mechanisms and Robotics
- Publisher
- ASME International
- Published
- 2013-06-24
- Volume
- 5
- Issue
- 3
- ISSN
- 1942-4302 (ISSN-L)
- 1942-4310
- OpenAlex
- W2072884984
- Cited by
- 174
- References
- 16
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solving the Robot-World/Hand-Eye Calibration Problem Using the Kronecker Product. https://app.cochat.ai/papers/10.1115/1.4024473
- The paper
- Shah, M. (2013). Solving the Robot-World/Hand-Eye Calibration Problem Using the Kronecker Product. Journal of Mechanisms and Robotics. https://doi.org/10.1115/1.4024473
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.