CoChat

Quantification of Blood-Brain Barrier Solute Permeability and Brain Transport by Multiphoton Microscopy

Shi, Lingyan, Zeng, Min, Sun, Yi, Fu, Bingmei M. · 2014 · Journal of Biomechanical Engineering
Cited by 96

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Development of an optimal systemic drug delivery strategy to the brain will require noninvasive or minimally invasive methods to quantify the permeability of the cerebral microvessel wall or blood-brain barrier (BBB) to various therapeutic agents and to measure their transport in the brain tissue. To address this problem, we used laser-scanning multiphoton microscopy to determine BBB permeability to solutes (P) and effective solute diffusion coefficients (Deff) in rat brain tissue 100–250 μm below the pia mater. The cerebral microcirculation was observed through a section of frontoparietal bone thinned with a microgrinder. Sodium fluorescein, fluorescein isothiocyanate (FITC)-dextrans, or Alexa Fluor 488-immunoglobulin G (IgG) in 1% bovine serum albumin (BSA) mammalian Ringer's solution was injected into the cerebral circulation via the ipsilateral carotid artery by a syringe pump at a constant rate of ∼3 ml/min. P and Deff were determined from the rate of tissue solute accumulation and the radial concentration gradient around individual microvessels in the brain tissue. The mean apparent permeability P values for sodium fluorescein (molecular weight (MW) 376 Da), dextran-4k, -20k, -40k, -70k, and IgG (MW ∼160 kDa) were 14.6, 6.2, 1.8, 1.4, 1.3, and 0.54 × 10−7 cm/s, respectively. These P values were not significantly different from those of rat pial microvessels for the same-sized solutes (Yuan et al., 2009, “Non-Invasive Measurement of Solute Permeability in Cerebral Microvessels of the Rat,” Microvasc. Res., 77(2), pp. 166–73), except for the small solute sodium fluorescein, suggesting that pial microvessels can be a good model for studying BBB transport of relatively large solutes. The mean Deff values were 33.2, 4.4, 1.3, 0.89, 0.59, and 0.47 × 10−7 cm2/s, respectively, for sodium fluorescein, dextran-4k, -20k, -40k, -70k, and IgG. The corresponding mean ratio of Deff to the free diffusion coefficient Dfree, Deff/Dfree, were 0.46, 0.19, 0.12, 0.12, 0.11, and 0.11 for these solutes. While there is a significant difference in Deff/Dfree between small (e.g., sodium fluorescein) and larger solutes, there is no significant difference in Deff/Dfree between solutes with molecular weights from 20,000 to 160,000 Da, suggesting that the relative resistance of the brain tissue to macromolecular solutes is similar over a wide size range. The quantitative transport parameters measured from this study can be used to develop better strategies for brain drug delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.4025892

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 96

Metadata

Authors
Shi, L., Zeng, M., Sun, Y., & Fu, B. M.
Venue
Journal of Biomechanical Engineering
Published
2014-02-13
Volume
136
Issue
3
Pages
031005-031005
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2056451525
Cited by
96
References
4
FWCI
2.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Blood-Brain Barrier Solute Permeability and Brain Transport by Multiphoton Microscopy. https://app.cochat.ai/papers/10.1115/1.4025892
The paper
Shi, L., Zeng, M., Sun, Y., & Fu, B. M. (2014). Quantification of Blood-Brain Barrier Solute Permeability and Brain Transport by Multiphoton Microscopy. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4025892

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.