The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
A Subject-Specific Musculoskeletal Modeling Framework to Predict In Vivo Mechanics of Total Knee Arthroplasty
Open accessAbstract
Musculoskeletal (MS) models should be able to integrate patient-specific MS architecture and undergo thorough validation prior to their introduction into clinical practice. We present a methodology to develop subject-specific models able to simultaneously predict muscle, ligament, and knee joint contact forces along with secondary knee kinematics. The MS architecture of a generic cadaver-based model was scaled using an advanced morphing technique to the subject-specific morphology of a patient implanted with an instrumented total knee arthroplasty (TKA) available in the fifth “grand challenge competition to predict in vivo knee loads” dataset. We implemented two separate knee models, one employing traditional hinge constraints, which was solved using an inverse dynamics technique, and another one using an 11-degree-of-freedom (DOF) representation of the tibiofemoral (TF) and patellofemoral (PF) joints, which was solved using a combined inverse dynamic and quasi-static analysis, called force-dependent kinematics (FDK). TF joint forces for one gait and one right-turn trial and secondary knee kinematics for one unloaded leg-swing trial were predicted and evaluated using experimental data available in the grand challenge dataset. Total compressive TF contact forces were predicted by both hinge and FDK knee models with a root-mean-square error (RMSE) and a coefficient of determination (R2) smaller than 0.3 body weight (BW) and equal to 0.9 in the gait trial simulation and smaller than 0.4 BW and larger than 0.8 in the right-turn trial simulation, respectively. Total, medial, and lateral TF joint contact force predictions were highly similar, regardless of the type of knee model used. Medial (respectively lateral) TF forces were over- (respectively, under-) predicted with a magnitude error of M < 0.2 (respectively > −0.4) in the gait trial, and under- (respectively, over-) predicted with a magnitude error of M > −0.4 (respectively < 0.3) in the right-turn trial. Secondary knee kinematics from the unloaded leg-swing trial were overall better approximated using the FDK model (average Sprague and Geers' combined error C = 0.06) than when using a hinged knee model (C = 0.34). The proposed modeling approach allows detailed subject-specific scaling and personalization and does not contain any nonphysiological parameters. This modeling framework has potential applications in aiding the clinical decision-making in orthopedics procedures and as a tool for virtual implant design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,021
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215
Analysis of musculoskeletal systems in the AnyBody Modeling System
Damsgaard, M., Rasmussen, J., Christensen, S. T., Surma, E., & de Zee, M. (2006) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2006.09.001 · Cited by 1,031
Self-citationSoft Tissue Restraints to Lateral Patellar Translation in the Human Knee
Desio, S. M., Burks, R. T., & Bachus, K. N. (1998) · The American Journal of Sports Medicine · doi:10.1177/03635465980260012701 · Cited by 982
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
Evaluation of the medial soft-tissue restraints of the extensor mechanism of the knee.
Conlan, T., Garth, W. P., & Lemons, J. E. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199305000-00007 · Cited by 835
Anatomy and biomechanics of the medial patellofemoral ligament
Amis, A. A., Firer, P., Mountney, J., Senavongse, W., & Thomas, N. P. (2003) · The Knee · doi:10.1016/s0968-0160(03)00006-1 · Cited by 711
Grand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & D'Lima, D. D. (2012) · Journal of Orthopaedic Research · doi:10.1002/jor.22023 · Cited by 596
Individual muscle contributions to support in normal walking
Anderson, F. C., & Pandy, M. G. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00073-5 · Cited by 566
Articular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Butler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513
Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
Benoit, D. L., Ramsey, D. K., Lamontagne, M., Xu, L., Wretenberg, P., & Renström, P. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.04.012 · Cited by 489
Muscle recruitment by the min/max criterion — a comparative numerical study
Rasmussen, J., Damsgaard, M., & Voigt, M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00191-3 · Cited by 453
Self-citationShelburne, K. B., Torry, M. R., & Pandy, M. G. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20255 · Cited by 366
Knee joint forces: prediction, measurement, and significance
D’Lima, D. D., Fregly, B. J., Patil, S., Steklov, N., & Colwell, C. W. (2012) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411911433372 · Cited by 215
Carbone, V., Fluit, R., Pellikaan, P., van der Krogt, M. M., Janssen, D., Damsgaard, M., Vigneron, L., Feilkas, T., Koopman, H. F. J. M., & Verdonschot, N. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.034 · Cited by 202
Self-citationThe Anatomy of the Medial Patellofemoral Ligament
Baldwin, J. L. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546509339909 · Cited by 194
Andersen, M. S., Damsgaard, M., MacWilliams, B., & Rasmussen, J. (2010) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840903067080 · Cited by 188
Self-citationKinematic analysis of over-determinate biomechanical systems
Andersen, M. S., Damsgaard, M., & Rasmussen, J. (2009) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840802459412 · Cited by 179
Self-citationInterpreting muscle function from EMG: lessons learned from direct measurements of muscle force
Roberts, T. J., & Gabaldon, A. M. (2008) · Integrative and Comparative Biology · doi:10.1093/icb/icn056 · Cited by 173
An implantable telemetry device to measure intra-articular tibial forces
D’Lima, D. D., Townsend, C. P., Arms, S. W., Morris, B. A., & Colwell, C. W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.011 · Cited by 172
The role of muscles in joint adaptation and degeneration
Herzog, W., Longino, D., & Clark, A. (2003) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-003-0402-6 · Cited by 171
Influence of Soft Structures on Patellar Three-Dimensional Tracking
HEEGAARD, J., LEYVRAZ, P.-F., KAMPEN, A. V., RAKOTOMANANA, L., RUBIN, P. J., & BLANKEVOORT, L. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00033 · Cited by 166
Simultaneous prediction of muscle and contact forces in the knee during gait
Lin, Y., Walter, J. P., Banks, S. A., et al. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.048 · Cited by 155
Andersen, M. S., Benoit, D. L., Damsgaard, M., Ramsey, D. K., & Rasmussen, J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.034 · Cited by 150
Self-citationOn validation of multibody musculoskeletal models
Lund, M. E., de Zee, M., Andersen, M. S., & Rasmussen, J. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911431516 · Cited by 141
Self-citationTotal hip joint prosthesis for in vivo measurement of forces and moments
Damm, P., Graichen, F., Rohlmann, A., Bender, A., & Bergmann, G. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.003 · Cited by 114
Mootanah, R., Imhauser, C. W., Reisse, F., Carpanen, D., Walker, R. W., Koff, M. F., Lenhoff, M., Rozbruch, S. R., Fragomen, A. T., Dewan, Z., et al. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.899588 · Cited by 112
Spectral elements and field separation for an acoustic fluid subject to cavitation
Sprague, M., & Geers, T. L. (2003) · Journal of Computational Physics · doi:10.1016/s0021-9991(02)00024-4 · Cited by 108
Co-Simulation of Neuromuscular Dynamics and Knee Mechanics During Human Walking
Thelen, D. G., Choi, K. W., & Schmitz, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026358 · Cited by 106
Westerhoff, P., Graichen, F., Bender, A., Rohlmann, A., & Bergmann, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.07.011 · Cited by 85
Anatomy and Biomechanics of the Posterior Cruciate Ligament, Medial and Lateral Sides of the Knee
Bowman, K. F., & Sekiya, J. K. (2010) · Sports Medicine and Arthroscopy Review · doi:10.1097/jsa.0b013e3181f917e2 · Cited by 79
Martelli, S., Valente, G., Viceconti, M., & Taddei, F. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.930134 · Cited by 76
Li, G., Zayontz, S., Most, E., Otterberg, E., Sabbag, K., & Rubash, H. E. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.28367 · Cited by 75
Clinical biomechanics of instability related to total knee arthroplasty
Athwal, K. K., Hunt, N. C., Davies, A. J., et al. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.11.004 · Cited by 73
Chen, Z., Zhang, X., Ardestani, M. M., Wang, L., Liu, Y., Lian, Q., He, J., Li, D., & Jin, Z. M. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914537476 · Cited by 73
Evaluating the effect of co-contraction in optimization models
Hughes, R. E., Bean, J. C., & Chaffin, D. B. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95277-c · Cited by 67
A mass–length scaling law for modeling muscle strength in the lower limb
Correa, T. A., & Pandy, M. G. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.08.024 · Cited by 64
Concurrent Prediction of Muscle and Tibiofemoral Contact Forces During Treadmill Gait
Guess, T. M., Stylianou, A. P., & Kia, M. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026359 · Cited by 54
Mellon, S., Grammatopoulos, G. A., Andersen, M. S., Pegg, E. C., Pandit, H. G., Murray, D. W., & Gill, H. S. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913483639 · Cited by 53
Self-citationEvaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials
Kia, M., Stylianou, A. P., & Guess, T. M. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.12.007 · Cited by 51
de Monsabert, B. G., Vigouroux, L., Bendahan, D., & Berton, É. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.10.007 · Cited by 49
Dual-Joint Modeling for Estimation of Total Knee Replacement Contact Forces During Locomotion
Hast, M. W., & Piazza, S. J. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023320 · Cited by 46
Muscle decomposition and recruitment criteria influence muscle force estimates
Holmberg, L. J., & Klarbring, A. (2011) · Multibody System Dynamics · doi:10.1007/s11044-011-9277-4 · Cited by 23
Mirakhorlo, M., Azghani, M., & Kahrizi, S. (2014) · PubMed · Cited by 20
Influence of minimally invasive total hip replacement on hip reaction forces and their orientations
Weber, T., Al-Munajjed, A. A., Verkerke, G. J., Dendorfer, S., & Renkawitz, T. F. (2014) · Journal of Orthopaedic Research® · doi:10.1002/jor.22710 · Cited by 18
Measuring functional outcome after total hip replacement with subject-specific hip joint loading
Weber, T., Dendorfer, S., Dullien, S., Grifka, J. K., Verkerke, G. J., & Renkawitz, T. F. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411912447728 · Cited by 17
van Duren, B. H., Pandit, H. G., Murray, D., & Gill, H. S. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.887697 · Cited by 4
Cited by
Altered Muscle Contributions are Required to Support the Stance Limb During Voluntary Toe-Walking
De Pieri, E., Romkes, J., Wyss, C., Brunner, R., & Viehweger, E. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.810560 · Cited by 12
Metadata
- Authors
- Marra, M. A., Vanheule, V., Fluit, R., Koopman, B. H. F. J. M., Rasmussen, J., Verdonschot, N., & Andersen, M. S.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2015-02-01
- Volume
- 137
- Issue
- 2
- Pages
- 020904-020904
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2100194686
- Cited by
- 278
- References
- 48
- FWCI
- 16.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.