Abstract
This paper details the design and fabrication process of a fully integrated soft humanoid robotic hand with five finger that integrate an embedded shape memory alloy (SMA) actuator and a piezoelectric transducer (PZT) flexure sensor. Several challenges including precise control of the SMA actuator, improving power efficiency, and reducing actuation current and response time have been addressed. First, a Ni-Ti SMA strip is pretrained to a circular shape. Second, it is wrapped with a Ni-Cr resistance wire that is coated with thermally conductive and electrically isolating material. This design significantly reduces actuation current, improves circuit efficiency, and hence reduces response time and increases power efficiency. Third, an antagonistic SMA strip is used to improve the shape recovery rate. Fourth, the SMA actuator, the recovery SMA strip, and a flexure sensor are inserted into a 3D printed mold which is filled with silicon rubber materials. The flexure sensor feeds back the finger shape for precise control. Fifth, a demolding process yields a fully integrated multifunctional soft robotic finger. We also fabricated a hand assembled with five fingers and a palm. We measured its performance and specifications with experiments. We demonstrated its capability of grasping various kinds of regular or irregular objects. The soft robotic hand is very robust and has a large compliance, which makes it ideal for use in an unstructured environment. It is inherently safe to human operators as it can withstand large impacts and unintended contacts without causing any injury to human operators or damage to the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft robotics: a bioinspired evolution in robotics
Kim, S., Laschi, C., & Trimmer, B. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.03.002 · Cited by 2,092
Meshworm: A Peristaltic Soft Robot With Antagonistic Nickel Titanium Coil Actuators
Seok, S., Onal, C. D., Cho, K.-J., Wood, R. J., Rus, D., & Kim, S. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2204070 · Cited by 665
Cited by
An Overview of Shape Memory Alloy-Coupled Actuators and Robots
Rodrigue, H., Wang, W., Han, M.-W., Kim, T. J. Y., & Ahn, S.-H. (2017) · Soft Robotics · doi:10.1089/soro.2016.0008 · Cited by 269
Metadata
- Authors
- She, Y., Li, C., Cleary, J., & Su, H.-J.
- Venue
- Journal of Mechanisms and Robotics
- Publisher
- ASME International
- Published
- 2015-05-01
- Volume
- 7
- Issue
- 2
- ISSN
- 1942-4302 (ISSN-L)
- 1942-4310
- OpenAlex
- W2005806111
- Cited by
- 205
- References
- 2
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Fabrication of a Soft Robotic Hand With Embedded Actuators and Sensors. https://app.cochat.ai/papers/10.1115/1.4029497
- The paper
- She, Y., Li, C., Cleary, J., & Su, H.-J. (2015). Design and Fabrication of a Soft Robotic Hand With Embedded Actuators and Sensors. Journal of Mechanisms and Robotics. https://doi.org/10.1115/1.4029497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.