Meshworm: A Peristaltic Soft Robot With Antagonistic Nickel Titanium Coil Actuators

Seok, Sangok, Onal, Cagdas Denizel, Cho, Kyu-Jin, Wood, Robert J., Rus, Daniela, Kim, Sangbae·2013·IEEE/ASME Transactions on Mechatronics

Abstract

This paper presents the complete development and analysis of a soft robotic platform that exhibits peristaltic locomotion. The design principle is based on the antagonistic arrangement of circular and longitudinal muscle groups of Oligochaetes. Sequential antagonistic motion is achieved in a flexible braided mesh-tube structure using a nickel titanium (NiTi) coil actuators wrapped in a spiral pattern around the circumference. An enhanced theoretical model of the NiTi coil spring describes the combination of martensite deformation and spring elasticity as a function of geometry. A numerical model of the mesh structures reveals how peristaltic actuation induces robust locomotion and details the deformation by the contraction of circumferential NiTi actuators. Several peristaltic locomotion modes are modeled, tested, and compared on the basis of speed. Utilizing additional NiTi coils placed longitudinally, steering capabilities are incorporated. Proprioceptive potentiometers sense segment contraction, which enables the development of closed-loop controllers. Several appropriate control algorithms are designed and experimentally compared based on locomotion speed and energy consumption. The entire mechanical structure is made of flexible mesh materials and can withstand significant external impact during operation. This approach allows a completely soft robotic platform by employing a flexible control unit and energy sources.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmech.2012.2204070

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. 10.1155/2008/520417 · doi:10.1155/2008/520417 · Paper page

Cited by

See all 665

Metadata

Authors
Seok, S., Onal, C. D., Cho, K.-J., Wood, R. J., Rus, D., & Kim, S.
Affiliations
  • Massachusetts Institute of Technology (US)
  • MIT Computer Science and Artificial Intelligence Laboratory (US)
  • Seoul National University (KR)
  • Harvard University (US)
Venue
IEEE/ASME Transactions on Mechatronics
Published
2013-10
Volume
18
Issue
5
Pages
1485-1497
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2071188031
Cited by
665
References
28
Citations by year
2026: 16 · 2025: 42 · 2024: 40 · 2023: 51 · 2022: 61 · 2021: 70 · 2020: 75 · 2019: 80 · 2018: 83 · 2017: 48 · 2016: 41 · 2015: 33 · 2014: 18 · 2013: 5
FWCI
17.84
Type
journal article
Language
en
Open access
closed
Locations
IEEE/ASME Transactions on Mechatronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Locomotion and Control
Keywords
soft robotics, peristaltic locomotion, antagonistic actuators, feedback control, locomotion speed, energy consumption, impact resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Meshworm: A Peristaltic Soft Robot With Antagonistic Nickel Titanium Coil Actuators. https://app.cochat.ai/papers/10.1109/tmech.2012.2204070
The paper
Seok, S., Onal, C. D., Cho, K.-J., Wood, R. J., Rus, D., & Kim, S. (2013). Meshworm: A Peristaltic Soft Robot With Antagonistic Nickel Titanium Coil Actuators. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2012.2204070

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.