CoChat

A Framework for In Silico Clinical Trials for Medical Devices Using Concepts From Model Verification, Validation, and Uncertainty Quantification

Bodner, Jeff, Kaul, Vikas · 2022 · Journal of Verification Validation and Uncertainty Quantification

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

The rising costs of clinical trials for medical devices in recent years has led to an increased interest in what are called in silico clinical trials, where simulation results are used to supplement or to replace those obtained from human patients. Here we present a framework for executing such a trial. This framework relies heavily on ideas already developed for model verification, validation, and uncertainty quantification. The framework uses results from an initial cohort of human patients as model validation data, recognizing that the best model credibility evidence usually comes from real patients. The validation exercise leads to an assessment of the model's suitability based on predefined acceptance criteria. If the model meets these criteria, then no additional human patients are required and the study endpoints that can be addressed using the model are met using the simulation results. Conversely, if the model is found to be inadequate, it is abandoned, and the clinical study continues using only human patients in a second cohort. Compared to other frameworks described in the literature based on Bayesian methods, this approach follows a strict model build-validate-predict structure. It can handle epistemic uncertainties in the model inputs, which is a common trait of models of biomedical systems. Another idea discussed here is that the outputs of engineering models rarely coincide with measures that are the basis for clinical endpoints. This article discusses how the link between the model and clinical measure can be established during the trial.

Overview

Integrity signals

Registry

Crossref · 10.1115/1.4053565

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 6

  1. Reporting of Computational Modeling Studies in Medical Device Submissions: Guidance for Industry and Food and Drug Administration Staff
  2. American Society of Mechanical Engineers, 2018, Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices
  3. 2010, Verification and Validation in Scientific Computing
  4. American Society of Mechanical Engineers, 2009, Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer
  5. American Society of Mechanical Engineers, 2019, Standard for Verification and Validation in Computational Solid Mechanics
  6. The Least Burdensome Provisions: Concept and Principles, Guidance for Industry and FDA Staff

Cited by

See all 8

Metadata

Authors
Bodner, J., & Kaul, V.
Affiliations
Medtronic (United States) (US)
Corresponding author
Bodner, Jeff
Venue
Journal of Verification Validation and Uncertainty Quantification
Published
2022-02-09
Volume
7
Issue
2
ISSN
  • 2377-2158 (ISSN-L)
  • 2377-2166
OpenAlex
W4226327246
Cited by
7
References
23
Citations by year
2025: 2 · 2024: 3 · 2023: 2
FWCI
1.30
Type
journal article
Language
en
Open access
closed
Locations
Journal of Verification Validation and Uncertainty Quantification (publishedVersion)
Topics
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Simulation Techniques and Applications
  • Physical Sciences › Engineering › Computational Mechanics › Probabilistic and Robust Engineering Design
Keywords
in silico clinical trials, medical devices, model verification, model validation, uncertainty quantification, epistemic uncertainty, clinical trial endpoints

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.