Use of Real-World Data for Enhancing Model Credibility: Applications to Medical Device Development
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Abstract Evaluating the credibility of computational models used in medical device development is increasingly important as medical devices become more complex and modeling takes on a more critical role in the device development process. While bench-testing based comparisons are common for assessing model credibility and have many advantages, such as control over test specimens and the ability to quantify outputs, the credibility assessments performed with bench tests often do not evaluate the clinical relevance of key aspects of model form (such as boundary conditions, constitutive models/properties, and geometries) selected when simulating in vivo conditions. Real-world data (outcomes data generated through clinical use of a device) offer an opportunity to assess the applicability and clinical relevance of a computational model. Although real-world data are frequently less controlled and more qualitative than benchtop data, real-world data are often a direct assessment of a particular clinical complication and therefore of high clinical relevance. Further, real-world data have the potential to reveal failure modes not previously identified in preclinical failure modes analysis, thereby motivating testing advancements. To review the use of clinical data in medical device modeling, this paper presents a series of examples related to tibial tray fracture that incorporate varying levels of benchtop data and real world data when evaluating model credibility. The merits and drawbacks of the credibility assessment for each example are discussed in order to provide practical and actionable guidance on the use of real-world data for establishing and demonstrating model credibility.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The medical devices modeling community has developed frameworks and methods to assess credibility of computational models for medical devices, including the ASME V&V40 2018 Standard, FDA Guidance [2], and various supporting documents [3–7].”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [5]
Citations
Cites
Knee Motions During Maximum Flexion in Fixed and Mobile-Bearing Arthroplasties
Banks, S., Bellemans, J., Nozaki, H., Whiteside, L. A., Harman, M., & Hodge, W. A. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000063121.39522.19 · Cited by 211
Applicability Analysis of Validation Evidence for Biomedical Computational Models
Pathmanathan, P., Gray, R. A., Romero, V. J., & Morrison, T. M. (2017) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4037671 · Cited by 68
Morrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019) · ASAIO Journal · doi:10.1097/mat.0000000000000996 · Cited by 68
Fracture of the metallic tibial tray following total knee replacement. Report of two cases.
Scott, R. D., Ewald, F. C., & Walker, P. S. (1984) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198466050-00021 · Cited by 60
FRACTURE OF THE METAL TIBIAL TRAY AFTER KINEMATIC TOTAL KNEE REPLACEMENT
Abernethy, P. J., Robinson, C. M., & Fowler, R. M. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b2.0780220 · Cited by 53
Evaluation of a testing method for the fatigue performance of total knee tibial trays
Ahir, S. P., Blunn, G. W., Haider, H., & Walker, P. S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00094-9 · Cited by 37
Motion of a mobile bearing knee allowing translation and rotation
Walker, P. S., Komistek, R. D., Barrett, D. S., Anderson, D. T., Dennis, D. A., & Sampson, M. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.28731 · Cited by 32
The incidence of implant fractures after knee arthroplasty
Gilg, M. M., Zeller, C. W., Leitner, L., Leithner, A., Labek, G., & Sadoghi, P. (2016) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-016-4160-8 · Cited by 22
Tibial tray fracture in a modern prosthesis with retrieval analysis
Callaghan, J. J., DeMik, D. E., Bedard, N. A., Odland, A. N., Kane, W. M., & Kurtz, S. M. (2018) · Arthroplasty Today · doi:10.1016/j.artd.2017.12.005 · Cited by 14
Biomechanical analysis of tibial tray fractures post total knee arthroplasty
Boran, S., Hurson, C. J., Synnott, K. A., & Keogh, P. (2005) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-005-0242-x · Cited by 11
Research works printed but not linked: 6
- US Food & Drug Administration, 2017, Use of Real-World Evidence to Support Regulatory Decision-Making for Medical Devices
- ASTM International, 2020, Standard Practice for Finite Element Analysis (FEA) of Non-Modular Metallic Orthopaedic Hip Femoral Stems
- ASTM International, 2014, Standard Guide for Finite Element Analysis (FEA) of Metallic Vascular Stents Subjected to Uniform Radial Loading
- ASME, 2018, Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices
- ASTM, 2019, Standard Practice for Cyclic Fatigue Testing of Metal Tibial Tray Components of Total Knee Joint Replacements
- U.S. Food & Drug Administration, 2021, Assessing the Credibility of Computational Modeling and Simulation in Medical Device Submissions, Draft Guidance for Industry and Food and Drug Administration Staff
Cited by
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
A Multimodal Deep Learning Model for the Classification of Breast Cancer Subtypes
Rabah, C. B., Sattar, A., Ibrahim, A., & Serag, A. (2025) · Diagnostics · doi:10.3390/diagnostics15080995 · Cited by 48
“Although retrospective studies have demonstrated the potential of AI in oncology, real-world validation is necessary to ensure the reliability, robustness, and clinical applicability of the model [57].”
A risk and credibility framework for in silico clinical trials of medical devices
Bischoff, J. E., Dharia, M. A., & Favre, P. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107813 · Cited by 20
Maquer, G., Mueri, C., Henderson, A., Bischoff, J. E., & Favre, P. (2024) · Annals of Biomedical Engineering · doi:10.1007/s10439-024-03452-w · Cited by 13
An Overview of the ASME V&V 40-2018 Standard
Horner, M. (2026) · Springer eBooks · doi:10.1007/978-3-032-09180-2_5
Horner, M., & Nagaraja, S. (2026) · Springer eBooks · doi:10.1007/978-3-032-09180-2_6
Metadata
- Authors
- Briant, P., Bischoff, J. E., Dharia, M. A., Le Navéaux, F., Li, X., Kulkarni, S., Levine, D., Ramos, D. O., & Afshari, P.
- Affiliations
- Exponent (United States) (US)
- Zimmer Biomet (United States) (US)
- Numalogics , 6750 Avenue de l'Esplanade, #290, Montreal, QC H2V1A2, Canada
- Abbott Laboratories , 5050 Nathan Lane North, Plymouth, MN 55442
- Neilsoft, Inc. , 7000 Executive Center Drive, Suite 210, Brentwood, TN 37027
- Purdue Polytechnic Institute , 635 South Lafayette Building Suite 128, South Bend, IN 46601
- Johnson and Johnson, Janssen Pharmaceuticals , 4691 Karson Creek Drive, Orange Park, FL 32065
- Johnson & Johnson (United States) (US)
- Venue
- Journal of Medical Devices
- Publisher
- ASME International
- Published
- 2022-03-22
- Volume
- 16
- Issue
- 3
- ISSN
- 1932-6181 (ISSN-L)
- 1932-619X
- OpenAlex
- W4213065772
- Cited by
- 6
- References
- 16
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 1
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Medical Devices (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- real-world data, model credibility, medical device development, computational modeling, knee arthroplasty, bench testing, clinical relevance, failure modes, in vivo simulation, model validation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.