Protein resistant surfaces: Comparison of acrylate graft polymers bearing oligo-ethylene oxide and phosphorylcholine side chains
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The objective of this work was to compare poly(ethylene glycol) (PEG) and phosphorylcholine (PC) moieties as surface modifiers with respect to their ability to inhibit protein adsorption. Surfaces were prepared by graft polymerization of the methacrylate monomers oligo(ethylene glycol) methyl ether methacrylate (OEGMA, MW 300, PEG side chains of length n=4.5) and 2-methacryloyloxyethyl phosphorylcholine (MPC, MW295). The grafted polymers thus contained short PEG chains and PC, respectively, as side groups. Grafting on silicon was carried out using surface-initiated atom transfer radical polymerization (ATRP). Graft density was controlled via the surface density of the ATRP initiator, and chain length of the grafts was controlled via the ratio of monomer to sacrificial initiator. The grafted surfaces were characterized by water contact angle, x-ray photoelectron spectroscopy, and atomic force microscopy. The effect of graft density and chain length on fibrinogen adsorption from buffer was investigated using radio labeling methods. Adsorption to both MPC- and OEGMA-grafted surfaces was found to decrease with increasing graft density and chain length. Adsorption on the MPC and OEGMA surfaces for a given chain length and density was essentially the same. Very low adsorption levels of the order of 7 ng/cm2 were seen on the most resistant surfaces. The effect of protein size on resistance to adsorption was studied using binary solutions of lysozyme (MW 14 600) and fibrinogen (MW 340 000). Adsorption levels in these experiments were also greatly reduced on the grafted surfaces compared to the control surfaces. It was concluded that at the lowest graft density, both proteins had unrestricted access to the substrate, and the relative affinities of the proteins for the substrate (higher affinity of fibrinogen) determined the composition of the layer. At the highest graft density also, where the adsorption of both proteins was very low, no preference for one or the other protein was evident, suggesting that adsorption did not involve penetration of the grafts and was occurring at the outer surface of the graft layer. It thus seems likely that preference among different proteins based on ability to penetrate the graft layer would occur, if at all, at a grafting density intermediate between 0.1 and 0.39 /cm2. Again the MPC and OEGMA surfaces behaved similarly. It is suggested that the main determinant of the protein resistance of these surfaces is the “water barrier layer” resulting from their hydrophilic character. In turn the efficacy of the water barrier depends on the monomer density in the graft layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Moro, T., Takatori, Y., Ishihara, K., Konno, T., Takigawa, Y., Matsushita, T., Chung, U.-I., Nakamura, K., & Kawaguchi, H. (2004) · Nature Materials · doi:10.1038/nmat1233 · Cited by 572
Self-citation
Cited by
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Zoppe, J. O., Ataman, N. C., Mocny, P., Wang, J., Moraes, J., & Klok, H.-A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00314 · Cited by 1,046
A review of the recent advances in antimicrobial coatings for urinary catheters
Singha, P., Locklin, J., & Handa, H. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.070 · Cited by 448
Morandi, G., Heath, L., & Thielemans, W. (2009) · Langmuir · doi:10.1021/la900452a · Cited by 405
Surface modification of biomaterials and biomedical devices using additive manufacturing
Bose, S., Robertson, S. F., & Bandyopadhyay, A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.003 · Cited by 305
Metadata
- Authors
- Feng, W., Zhu, S., Ishihara, K., & Brash, J. L.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2006-03-01
- Volume
- 1
- Issue
- 1
- Pages
- 50-60
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W1992528022
- Cited by
- 154
- References
- 4
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.