Improved volume-averaged model for steady and pulsed-power electronegative discharges
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An improved volume-averaged global model is developed for a cylindrical (radius R, length L) electronegative (EN) plasma that is applicable over a wide range of electron densities, electronegativities, and pressures. It is applied to steady and pulsed-power oxygen discharges. The model incorporates effective volume and surface loss factors for positive ions, negative ions, and electrons combining three electronegative discharge regimes: a two-region regime with a parabolic EN core surrounded by an electropositive edge, a one-region parabolic EN plasma, and a one-region flat-topped EN plasma, spanning the plasma parameters and gas pressures of interest for low pressure processing (below a few hundred millitorr). Pressure-dependent effective volume and surface loss factors are also used for the neutral species. A set of reaction rate coefficients, updated from previous model calculations, is developed for oxygen for the species O2, O2(Δg1), O, O2+, O+, and O−, based on the latest published cross-section sets and measurements. The model solutions yield all of the quantities above together with such important processing quantities such as the neutral/ion flux ratio ΓO∕Γi, with the discharge aspect ratio 2R∕L and pulsed-power period and duty ratio (pulse on-time/pulse period) as parameters. The steady discharge results are compared to an experiment, giving good agreement. For steady discharges, increasing 2R∕L from 1 to 6 leads to a factor of 0.45 reduction in ΓO∕Γi. For pulsed discharges with a fixed duty ratio, ΓO∕Γi is found to have a minimum with respect to pulse period. A 25% duty ratio pulse reduces ΓO∕Γi by a factor of 0.75 compared to the steady-state case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Plasma Discharges and Materials Processing
Lieberman, M. A., & Lichtenberg, A. J. (2005) · doi:10.1002/0471724254 · Cited by 4,748
Self-citation
Cited by
Global model of low-temperature atmospheric-pressure He + H2O plasmas
Liu, D. X., Bruggeman, P., Iza, F., Rong, M. Z., & Kong, M. G. (2010) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/19/2/025018 · Cited by 463
Oxygen discharges diluted with argon: dissociation processes
Gudmundsson, J. T., & Thorsteinsson, E. G. (2007) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/16/2/025 · Cited by 337
Self-citationA global (volume averaged) model of a nitrogen discharge: I. Steady state
Thorsteinsson, E. G., & Gudmundsson, J. T. (2009) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/18/4/045001 · Cited by 132
Gudmundsson, J. T., Kawamura, E., & Lieberman, M. A. (2013) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/22/3/035011 · Cited by 107
Self-citationMrózek, K., Dytrych, T., Moliš, P., Dániel, V., & Obrusník, A. (2021) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/ac36ac · Cited by 35
Metadata
- Authors
- Kim, S., Lieberman, M. A., Lichtenberg, A. J., & Gudmundsson, J. T.
- Venue
- Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films
- Publisher
- American Vacuum Society
- Published
- 2006-10-10
- Volume
- 24
- Issue
- 6
- Pages
- 2025-2040
- ISSN
- 0734-2101 (ISSN-L)
- 1520-8559
- OpenAlex
- W1970620704
- Cited by
- 126
- References
- 1
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.