Sublithographic vertical gold nanogap for label-free electrical detection of protein-ligand binding
Open accessThe DOI matches its Crossref record.
Abstract
Label-free electrical detection of protein-ligand binding using a vertical gold nanogap is presented. A sublithographic nanogap was created using a sacrificial ultrathin film deposited by atomic layer deposition (ALD) in a process similar to the formation of a cantilever in microelectromechanical system processing. Due to the atomic precision of the sacrificial Al2O3 thickness by ALD, a 7nm nanogap was successfully fabricated. After binding streptavidin to biotin on the gold surface, an electrical current was measured for various voltages. A dramatic current increase was observed in the case of biotin-streptavidin binding in comparison with the other two cases: a control group filled with air and a biotin-only binding group. There was a minimal current change in the cases of the biotin-PBST group, the biotin-BSA group, and the biotin-saturated streptavidin group, as compared with the biotin-streptavidin group. At a 0.1μg∕ml concentration of streptavidin (1.5nM), the current difference before and after the protein binding was amplified by approximately 3000-fold with 17nm nanogap. Also, the detection sensitivity of the vertical nanogap as the gap size varied was investigated. As the size of biotin-streptavidin binding is the most comparable to 12nm nanogap, the highest sensitivity was shown in the 12nm gap device. 7nm nanogap can be used to detect smaller size of biomolecule than that of biotin streptavidin. This arrayable, two-terminal microdevice could be tested for use on a wide range of other biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Self-citationElectrical nanogap devices for biosensing
Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70201-7 · Cited by 326
Chakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Dwivedi, P., & Kranti, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2640192 · Cited by 87
“The thickness of the cavity was considered to be 10 nm because thickness of biotin functionalized layer and of streptavidin are within 3–5 nm and 5 nm respectively, and 10 nm cavity thickness (∼= Tox) is appropriate for recognizing the nanosize target proteins [27], [44].”
BackgroundDas, A., Rewari, S., Kanaujia, B. K., Deswal, S. S., & Gupta, R. S. (2023) · Journal of Computational Electronics · doi:10.1007/s10825-023-02008-w · Cited by 67
“The size of streptavidin and biotin is roughly 5 nm [45], whereas that of protein lies in the micro–femtometer range [44, 46].”
Background
Metadata
- Authors
- Jang, D.-Y., Kim, Y.-P., Kim, H.-S., Ko Park, S.-H., Choi, S.-Y., & Choi, Y.-K.
- Venue
- Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Publisher
- American Vacuum Society
- Published
- 2007-03-01
- Volume
- 25
- Issue
- 2
- Pages
- 443-447
- ISSN
- 1071-1023 (ISSN-L)
- 1520-8567
- OpenAlex
- W2076346726
- Cited by
- 74
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.