The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Applicability of Transconductance-to-Current Ratio ( $g_{\mathrm {m}}/I_{\mathrm {ds}}$ ) as a Sensing Metric for Tunnel FET Biosensors
Abstract
In this paper, we propose and evaluate the feasibility of transconductance-to-current ratio (gm/Ids) as a sensing metric for a tunnel field-effect transistor (TFET)-based dielectric modulated biosensor. Focusing on the enhancement of the values of gm/Idsand current ratio at lower current levels to signify the presence of biomolecules in the dielectric cavity of TFET biosensor, the metric can be used not only for sensitivity but also for selectivity as the current ratio changes appreciably for the three different types of biomolecules, namely, Streptavidin, Biotin, and APTES. The gm/Idsextraction takes into account the operation at low power consumption, i.e., in the subthreshold region, which is most sensitive for biomolecule detection. The sensing methodology is governed by the location of the biomolecules within the cavity, and is less dependent on the fill-in factor. This paper highlights new opportunities to identify the sensing metric in TFET-based dielectric modulated biosensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The gm/Ids method achieves lower power dissipation for biosensing application.
“This method focuses on the variation of transconductanceto-current ratio (g m /I ds ) with drain current because the parameter shows a noticeable variation for biomolecules with different dielectric constants in subthreshold region, which achieves lower power dissipation for biosensing application.”
From A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application (2021) · cites this paper as [18]
The transconductance-to-current ratio (gm/Ids) shows a noticeable variation for biomolecules with different dielectric constants in the subthreshold region.
“This method focuses on the variation of transconductanceto-current ratio (g m /I ds ) with drain current because the parameter shows a noticeable variation for biomolecules with different dielectric constants in subthreshold region, which achieves lower power dissipation for biosensing application.”
From A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application (2021) · cites this paper as [18]
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Flagged first, then by citations
Research works printed but not linked: 51
- 10.1109/4.487994 · DOI
- 10.1109/4.597291 · DOI
- 10.1016/j.sse.2013.12.010 · DOI
- 10.1016/j.sse.2008.04.003 · DOI
- 10.1038/srep22554 · DOI
- 10.1063/1.2757593 · DOI
- 10.1109/LED.2010.2055829 · DOI
- 10.1109/TED.2011.2168226 · DOI
- 10.1109/4.535416 · DOI
- gao, 2010, Subthreshold regime has the optimal sensitivity for nanowire FET biosensors, Nano Lett, 10, 547, 10.1021/nl9034219 · DOI · Paper page
- 10.1038/nature10679 · DOI
- 10.1063/1.3300838 · DOI
- 10.1109/TED.2007.899389 · DOI
- 10.1038/nnano.2007.313 · DOI · Paper page
- 10.1021/acs.chemrev.5b00608 · DOI
- 10.1038/nnano.2007.180 · DOI · Paper page
- 10.1088/0957-4484/20/45/455502 · DOI
- 10.1016/S1369-7021(10)70201-7 · DOI
- 10.1109/LED.2013.2283858 · DOI · Paper page
- 10.1063/1.4745769 · DOI
- 10.1109/TED.2010.2076152 · DOI
- 10.1088/0957-4484/22/13/135502 · DOI · Paper page
- 10.1016/j.nantod.2011.02.001 · DOI
- 10.1109/JSEN.2010.2062502 · DOI
- im, 2009, Low noise current readout circuit for point-ofcare testing application, 16th Korean Conf Semicond Tech Dig, 450
- 10.1016/j.mee.2013.12.031 · DOI
- 10.1063/1.4757000 · DOI
- 10.1109/TED.2007.908596 · DOI
- 10.1063/1.4723843 · DOI
- 10.1016/j.snb.2013.03.028 · DOI
- 10.1088/0957-4484/26/14/145201 · DOI
- 10.1016/j.mee.2015.10.005 · DOI
- 10.1063/1.4804577 · DOI
- 10.1109/TED.2015.2390774 · DOI
- 10.1109/TNANO.2015.2396899 · DOI · Paper page
- 10.1016/j.spmi.2015.07.052 · DOI
- 10.1021/nl301623p · DOI
- 10.1109/LED.2011.2146750 · DOI
- 10.1109/TED.2008.2005168 · DOI
- 10.1016/j.snb.2013.11.123 · DOI
- 10.1021/nl1010965 · DOI
- 10.1109/LED.2010.2046011 · DOI
- 10.1109/TED.2005.860659 · DOI
- 10.1016/j.jcis.2006.08.055 · DOI
- 10.1109/TED.2007.909059 · DOI
- 10.1109/LED.2016.2574821 · DOI
- 10.1063/1.3291617 · DOI
- 10.1016/0022-3697(60)90035-4 · DOI
- 2016, Atlas User s Manual Device Simulation Software
- 10.1116/1.2713403 · DOI
- 10.1016/j.sse.2011.06.019 · DOI
Cited by
Sorted by citations
A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application
Li, C., Liu, F., Han, R., & Zhuang, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3074906 · Cited by 60
Metadata
- Authors
- Dwivedi, P., & Kranti, A.
- Affiliations
- Indian Institute of Technology Indore (IN)
- Venue
- IEEE Sensors Journal
- Published
- 2017-02-15
- Volume
- 17
- Issue
- 4
- Pages
- 1030-1036
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2567335776
- Cited by
- 87
- References
- 1
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 13 · 2023: 14 · 2022: 10 · 2021: 15 · 2020: 9 · 2019: 2 · 2018: 4
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- Council of Scientific and Industrial Research, Government of India (22(0688)/15/EMR-II)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- tunnel field-effect transistor, TFET biosensor, dielectric modulation, biomolecule detection, subthreshold operation, low-power sensing, streptavidin, biotin, 3-aminopropyltriethoxysilane, sensitivity and selectivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review