The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
What can electron paramagnetic resonance tell us about the Si/SiO2 system?
Abstract
Electron paramagnetic resonance (EPR) measurements of Si/SiO2 systems began over 30 years ago. Most EPR studies of Si/SiO2 systems have dealt with two families of defects: Pb centers and E′ centers. Several variants from each group have been observed in a wide range of Si/SiO2 samples. Some of the most basic aspects of this extensive, body of work remain controversial. EPR is an extraordinary powerful analytical tool quite widely utilized in chemistry, biomedical research, and solid state physics. Although uniquely well suited for metal–oxide–silicon (MOS) device studies, its capabilities are not widely understood in the MOS research and development community. The impact of EPR has been limited in the MOS community by a failure of EPR spectroscopists to effectively communicate with other engineers and scientists in the MOS community. In this article we hope to, first of all, ameliorate the communications problem by providing a brief but quantitative introduction to those aspects of EPR which are most relevant to MOS systems. We review, critically, those aspects of the MOS/EPR literature which are most relevant to MOS technology and show how this information can be used to develop physically based reliability models. Finally, we briefly review EPR work dealing with impurity defects in oxide thin films.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Magnetic Resonance
Slichter, C. P. (1990) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-09441-9 · Cited by 5,520
Electron Paramagnetic Resonance: Elementary Theory and Practical Applications
Weil, J. A., Bolton, J. R., Wertz, J. E., & Buckmaster, H. A. (1995) · Physics Today · doi:10.1063/1.2808029 · Cited by 1,013
Hole traps and trivalent silicon centers in metal/oxide/silicon devices
Lenahan, P. M., & Dressendorfer, P. V. (1984) · Journal of Applied Physics · doi:10.1063/1.332937 · Cited by 725
Self-citationPoindexter, E. H., Caplan, P. J., Deal, B. E., & Razouk, R. R. (1981) · Journal of Applied Physics · doi:10.1063/1.328771 · Cited by 561
Spin-Dependent Recombination on Silicon Surface
Lepine, D. J. (1972) · Physical Review B · doi:10.1103/physrevb.6.436 · Cited by 362
Interface traps and P b centers in oxidized (100) silicon wafers
Gerardi, G. J., Poindexter, E. H., Caplan, P. J., & Johnson, N. M. (1986) · Applied Physics Letters · doi:10.1063/1.97611 · Cited by 322
Effects of ionizing radiation on oxidized silicon surfaces and planar devices
Snow, E. H., Grove, A. S., & Fitzgerald, D. J. (1967) · Proceedings of the IEEE · doi:10.1109/proc.1967.5776 · Cited by 316
Surface recombination in semiconductors
Fitzgerald, D. J., & Grove, A. S. (1968) · Surface Science · doi:10.1016/0039-6028(68)90182-9 · Cited by 224
Atomistic Structure of Band-Tail States in Amorphous Silicon
Dong, J., & Drabold, D. A. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.1928 · Cited by 138
On the structures of hydrogen-associated defect centers in irradiated high-purity a-SiO2:OH
Tsai, T. E., & Griscom, D. L. (1987) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(87)80300-9 · Cited by 115
ESR studies of hydrogen hyperfine spectra in irradiated vitreous silica
Vitko, J. (1978) · Journal of Applied Physics · doi:10.1063/1.324473 · Cited by 111
Conley, J. F., Lenahan, P. M., Evans, H. L., Lowry, R. K., & Morthorst, T. J. (1994) · Journal of Applied Physics · doi:10.1063/1.358428 · Cited by 90
Self-citationYount, J. T., Lenahan, P. M., & Dunn, G. J. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.211423 · Cited by 30
Self-citation
Cited by
Stochastic charge trapping in oxides: From random telegraph noise to bias temperature instabilities
Grasser, T. (2012) · Microelectronics Reliability · doi:10.1016/j.microrel.2011.09.002 · Cited by 554
Total Ionizing Dose Effects in MOS and Low-Dose-Rate-Sensitive Linear-Bipolar Devices
Fleetwood, D. M. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2259260 · Cited by 377
Radiation effects and hardening of MOS technology: devices and circuits
Hughes, H. L., & Benedetto, J. M. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.812928 · Cited by 326
Cochrane, C. J., Lenahan, P. M., & Lelis, A. J. (2011) · Journal of Applied Physics · doi:10.1063/1.3530600 · Cited by 96
Self-citation
Metadata
- Authors
- Lenahan, P. M., & Conley, J. F.
- Venue
- Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Publisher
- American Vacuum Society
- Published
- 1998-07-01
- Volume
- 16
- Issue
- 4
- Pages
- 2134-2153
- ISSN
- 1071-1023 (ISSN-L)
- 1520-8567
- OpenAlex
- W2170109091
- Cited by
- 352
- References
- 13
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.