CoChat

Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography

Open access
Jiao, Shuliang, Wang, Lihong V. · 2002 · Journal of Biomedical Optics
Cited by 154

The DOI matches its Crossref record.

Abstract

Two-dimensional depth-resolved Jones-matrix images of scattering biological tissues were measured with novel double-source double-detector polarization-sensitive optical coherence tomography (OCT). The Jones matrix can be determined in a single scan with this OCT system. The experimental results show that this system can be effectively applied to the measurement of soft tissues, which are less stable than hard tissues. Polarization parameters such as diattenuation, birefringence, and orientation of the fast axis can be extracted through decomposition of the measured Jones matrix. The Jones matrix of thermally treated porcine tendon showed a reduction of birefringence from thermal damage. The Jones matrices of porcine skin and bovine cartilage also revealed that the density and orientation of the collagen fibers in porcine skin and bovine cartilage are not distributed as uniformly as in porcine tendon. Birefringence is sensitive to changes in tissue because it is based on phase contrast.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.1483878

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 154

Metadata

Authors
Jiao, S., & Wang, L. V.
Venue
Journal of Biomedical Optics
Published
2002
Volume
7
Issue
3
Pages
350
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2096516121
Cited by
154
References
0
FWCI
8.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography. https://app.cochat.ai/papers/10.1117/1.1483878
The paper
Jiao, S., & Wang, L. V. (2002). Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography. Journal of Biomedical Optics. https://doi.org/10.1117/1.1483878

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.