The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Imaging skin pathology with polarized light
Open accessAbstract
Linearly polarized light that illuminates skin is backscattered by superficial layers and rapidly depolarized by birefringent collagen fibers. It is possible to distinguish such superficially backscattered light from the total diffusely reflected light that is dominated by light penetrating deeply into the dermis. The method involves acquisition of two images through an analyzing linear polarizer in front of the camera, one image (I par) acquired with the analyzer oriented parallel to the polarization of illumination and one image (I per) acquired with the analyzer oriented perpendicular to the illumination. An image based on the polarization ratio, Pol5(I par-I per)/(I par+I per), is created. This paper compares normal light images, represented by I per , and Pol images of various skin pathologies in a pilot clinical study using incoherent visible-spectrum light. Images include pigmented skin sites (freckle, tattoo, pigmented nevi) and unpigmented skin sites [nonpigmented intradermal nevus, neurofibroma, actinic keratosis, malignant basal cell carcinoma, squamous cell carcinoma, vascular abnormality (venous lake), burn scar]. Images of a shadow cast from a razor blade onto a forearm skin site illustrate the behavior of Pol values near the shadow edge. Near the shadow edge, Pol approximately doubles in value because no I per photons are superficially scattered into the shadow-edge pixels by the shadow region while I par photons are directly backscattered from the superficial layer of these pixels. This result suggests that the point spread function in skin for cross-talk between Pol pixels has a half-width-half-max of about 390 µm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“some medical optical imaging techniques use polarized light including polarization-sensitive OCT, polarized light elastic scattering spectroscopy, and cross-polarized light imaging.149–151”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [150]
In the citing paper
“In addition, changes in the polarisation state of light can be used to provide information about tissues, including the superficial layers of the skin, by characterising the depolarisation of light as it propagates [88,89].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [88]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M. M., Grossman, M. C., Esterowitz, D., Webb, R. H., & Anderson, R. R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,090
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 884
Perelman, L. T., Backman, V., Wallace, M. B., Zonios, G. I., Manoharan, R., Nusrat, A., Shields, S. J., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 492
(1998) · Cited by 445
Demos, S. G., & Alfano, R. R. (1997) · Applied Optics · doi:10.1364/ao.36.000150 · Cited by 407
Backman, V., Gurjar, R. S., Badizadegan, K., Itzkan, I., Dasari, R. R., Perelman, L. T., & Feld, M. S. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796325 · Cited by 396
Imaging superficial tissues with polarized light
Jacques, S. L., Roman, J. R., & Lee, K. C. L. (2000) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(2000)26:2 · Cited by 370
Self-citationPolarized Light Examination and Photography of the Skin
Anderson, R. R. (1991) · Archives of Dermatology · doi:10.1001/archderm.1991.01680060074007 · Cited by 310
Use of polarized light to discriminate short-path photons in a multiply scattering medium
Schmitt, J. M., Gandjbakhche, A., & Bonner, R. F. (1992) · Applied Optics · doi:10.1364/ao.31.006535 · Cited by 293
Yao, G., & Wang, L. V. (1999) · Optics Letters · doi:10.1364/ol.24.000537 · Cited by 232
Flagged first, then by citations
Research works printed but not linked: 1
- Yao, 1999, Appl. Opt., 24, 537
Cited by
Sorted by citations
Items 101–200 of 582
Toyoda, M., Luo, Y., Makino, T., Matsui, C., & Morohashi, M. (1999) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1038/sj.jidsp.5640194 · Cited by 42
Côté, D. C., & Vitkin, I. A. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629683 · Cited by 42
Optical properties of the human skin / Optičke osobine ljudske kože
Gajinov, Z., Matić, M., Prćić, S., & Đuran, V. (2010) · Serbian Journal of Dermatology and Venerology · doi:10.2478/v10249-011-0029-5 · Cited by 42
Infrared Imaging Tools for Diagnostic Applications in Dermatology.
Gurjarpadhye, A. A., Parekh, M. B., Dubņika, A., Rajadas, J., & Inayathullah, M. (2015) · PubMed · Cited by 41
Analysis of the depolarizing properties of irradiated pig skin
Boulvert, F., Boulbry, B., Brun, G. L., Jeune, B. L., Rivet, S., & Cariou, J. (2004) · Journal of Optics A Pure and Applied Optics · doi:10.1088/1464-4258/7/1/003 · Cited by 41
Depolarization Remote Sensing by Orthogonality Breaking
Fade, J., & Alouini, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.043901 · Cited by 38
Vizet, J., Manhas, S. S., Tran, J., Validire, P., Benali, A., Garcia‐Caurel, E., Pierangelo, A., Martino, A. D., & Pagnoux, D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071106 · Cited by 39
Chue-Sang, J. J., Bai, Y., Stoff, S., Gonzalez, M., Holness, N. A., Gomes, J., Jung, R., Gandjbakhche, A., Chernomordik, V. V., & Ramella‐Roman, J. C. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.8.086010 · Cited by 39
Self-citationElliptically polarized light for depth resolved optical imaging
Silva, A. D., Deumié, C., & Vanzetta, I. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002907 · Cited by 38
Duan, L., Marvdashti, T., Lee, A., Tang, J. Y., & Bowden, A. K. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003717 · Cited by 38
Thompson, A. J., Coda, S., Sörensen, M. B., Kennedy, G. T., Patalay, R., Waitong‐Brämming, U., Beule, P. D., Neil, M. A. A., Andersson‐Engels, S., Bendsøe, N., et al. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201100126 · Cited by 38
Optimal discrimination of multiple regions with an active polarimetric imager
Anna, G., Goudail, F., & Dolfi, D. (2011) · Optics Express · doi:10.1364/oe.19.025367 · Cited by 37
Out-of-plane Stokes imaging polarimeter for early skin cancer diagnosis
Ghassemi, P., Lemaillet, P., Ramella‐Roman, J. C., Shupp, J. W., Venna, S. S., Boisvert, M. E., Flanagan, K. E., Jordan, M. H., & Germer, T. A. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.076014 · Cited by 37
Self-citationChue-Sang, J. J., Bai, Y., Stoff, S., Straton, D., Ramaswamy, S. D., & Ramella‐Roman, J. C. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071109 · Cited by 36
Self-citationRotating linear polarization imaging technique for anisotropic tissues
Liao, R., Zeng, N., Jiang, X., Li, D., Yun, T., He, Y., & Ma, H. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3442730 · Cited by 35
Vannier, N., Goudail, F., Plassart, C., Boffety, M., Feneyrou, P., Leviandier, L., Galland, F., & Bertaux, N. (2016) · Applied Optics · doi:10.1364/ao.55.002881 · Cited by 35
Pathological crystal imaging with single‐shot computational polarized light microscopy
Bai, B., Wang, H., Liu, T., Rivenson, Y., FitzGerald, J. D., & Özcan, A. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201960036 · Cited by 35
Shirvany, R., Chabert, M., & Tourneret, J. (2012) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2012.2202242 · Cited by 35
A Monte Carlo study of penetration depth and sampling volume of polarized light in turbid media
Guo, X., Wood, M. F. G., & Vitkin, I. A. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.09.043 · Cited by 35
López-Téllez, J. M., & Bruce, N. C. (2014) · Applied Optics · doi:10.1364/ao.53.005359 · Cited by 34
Multimodal facial color imaging modality for objective analysis of skin lesions
Bae, Y., Nelson, J. S., & Jung, B. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3006056 · Cited by 34
Principal component model of multispectral data for near real-time skin chromophore mapping
Kainerstorfer, J. M., Ehler, M., Amyot, F., Hassan, M., Demos, S. G., Chernomordik, V., Hitzenberger, C. K. F., Gandjbakhche, A., & Riley, J. D. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3463010 · Cited by 33
Polarized photoacoustic microscopy for vectorial-absorption-based anisotropy detection
Zhang, Z., Shi, Y., Xiang, L., & Xing, D. (2018) · Optics Letters · doi:10.1364/ol.43.005267 · Cited by 33
Li, P., Liu, C., Li, X., He, H., & Ma, H. (2016) · Applied Optics · doi:10.1364/ao.55.007468 · Cited by 32
Expression of target optical properties in subsurface polarization-gated imaging
Nothdurft, R. E., & Yao, G. (2005) · Optics Express · doi:10.1364/opex.13.004185 · Cited by 32
Review of polarization-based technology for biomedical applications
Guan, C., Zeng, N., & He, H. (2024) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545824300027 · Cited by 30
A polarized multispectral imaging system for quantitative assessment of hypertrophic scars
Ghassemi, P., Travis, T. E., Moffatt, L. T., Shupp, J. W., & Ramella‐Roman, J. C. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003337 · Cited by 31
Self-citationShukla, P., Sumathi, R., Gupta, S., & Pradhan, A. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001704 · Cited by 31
Alali, S., AITKEN, K. J., Schröder, A., Gribble, A., Bägli, D., & Vitkin, I. A. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000621 · Cited by 30
Polarized light camera to guide surgical excision of skin cancers
Jacques, S. L., Samatham, R. V., Isenhath, S., & Lee, K. C. L. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761823 · Cited by 30
Self-citationSardar, D. K., Yow, R. M., Tsin, A. T. C., & Sardar, R. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2065867 · Cited by 30
Contrast optimization in broadband passive polarimetric imaging
Boffety, M., Hu, H., & Goudail, F. (2014) · Optics Letters · doi:10.1364/ol.39.006759 · Cited by 29
The value of polarization in camera-based photoplethysmography
Trumpp, A., Bauer, P. L., Rasche, S., Malberg, H., & Zaunseder, S. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002822 · Cited by 29
Zhou, X. Y., Maloufi, S., Louie, D. C., Zhang, N., Liu, Q., Lee, T. K., & Tang, S. (2021) · Biomedical Optics Express · doi:10.1364/boe.424709 · Cited by 30
Active polarimetric imager with near infrared laser illumination for adaptive contrast optimization
Vannier, N., Goudail, F., Plassart, C., Boffety, M., Feneyrou, P., Leviandier, L., Galland, F., & Bertaux, N. (2015) · Applied Optics · doi:10.1364/ao.54.007622 · Cited by 29
Shen, F., Zhang, M., Guo, K., Zhou, H., Peng, Z., Cui, Y., Wang, F., Gao, J. X., & Guo, Z. (2019) · Optics Express · doi:10.1364/oe.27.028337 · Cited by 29
Polarized Reflectance Spectroscopy for Pre-Cancer Detection
Sokolov, K., Nieman, L. T., Myakov, A. V., & Gillenwater, A. M. (2004) · Technology in Cancer Research & Treatment · doi:10.1177/153303460400300101 · Cited by 29
Overview of Optical Biosensing Techniques
Abdulhalim, I. S., Zourob, M. M., & Lakhtakia, A. (2007) · doi:10.1002/9780470061565.hbb040 · Cited by 29
Polarization image segmentation of radiofrequency ablated porcine myocardial tissue
Ahmad, I., Gribble, A., Murtza, I., Ikram, M., Pop, M., & Vitkin, I. A. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175173 · Cited by 28
Maximum likelihood method for calibration of Mueller polarimeters in reflection configuration
Hu, H., Garcia‐Caurel, E., Anna, G., & Goudail, F. (2013) · Applied Optics · doi:10.1364/ao.52.006350 · Cited by 28
Ney, M. S., & Abdulhalim, I. S. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.12.125007 · Cited by 28
Hybrid complete Mueller polarimeter based on phase modulators
Martínez‐Ponce, G., Solano, C., & Pérez-Barrios, C. (2011) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2010.12.011 · Cited by 27
Ahmad, I., Ahmad, M., Khan, K. M., & Ikram, M. (2016) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2016.04.004 · Cited by 27
Poulikakos, L. V., Lawrence, M., Barton, D. R., Jeffrey, S. S., & Dionne, J. A. (2020) · ACS Photonics · doi:10.1021/acsphotonics.0c01303 · Cited by 27
Transformation of full 4 × 4 Mueller matrices: a quantitative technique for biomedical diagnosis
He, H., Chang, J., He, C., & Ma, H. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2210878 · Cited by 27
Contrast definition for optical coherent polarimetric images
Goudail, F., & Réfrégier, P. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.22 · Cited by 27
Siegel, M. P., Kim, Y. L., Roy, H. K., Wali, R. K., & Backman, V. (2006) · Applied Optics · doi:10.1364/ao.45.000335 · Cited by 27
Anomalous behavior of depolarization of light in a turbid medium
Ghosh, N., Gupta, P. K., Pradhan, A., & Majumder, S. K. (2006) · Physics Letters A · doi:10.1016/j.physleta.2006.01.053 · Cited by 27
Qi, J., He, H., Lin, J., Dong, Y., Chen, D., Ma, H., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201700139 · Cited by 26
Non-Contact Dermatoscope with Ultra-Bright Light Source and Liquid Lens-Based Autofocus Function
Fricke, D., Denker, E., Heratizadeh, A., Werfel, T., Meinhardt‐Wollweber, M., & Roth, B. (2019) · Applied Sciences · doi:10.3390/app9112177 · Cited by 26
GWAS Analysis of 17,019 Korean Women Identifies the Variants Associated with Facial Pigmented Spots
Shin, J., Leem, S., Kim, B., Kim, Y., Lee, S., Song, H. J., Seo, J. Y., Park, S. G., Won, H., & Kang, N. G. (2020) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2020.08.007 · Cited by 27
Yan, S., Jacques, S. L., Ramella‐Roman, J. C., & Fang, Q. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.8.083015 · Cited by 26
Self-citationMultispectral Polarization Imaging for Observing Blood Oxygen Saturation in Skin Tissue
Arimoto, H. (2006) · Applied Spectroscopy · doi:10.1366/000370206776593672 · Cited by 26
Early diagnosis of teeth erosion using polarized laser speckle imaging
Nader, C. A., Pellen, F., Loutfi, H., Mansour, R., Jeune, B. L., Brun, G. L., & Abboud, M. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071103 · Cited by 26
Registration scheme suitable to Mueller matrix imaging for biomedical applications
Guyot, S., Anastasiadou, M., Deléchelle, É., & Martino, A. D. (2007) · Optics Express · doi:10.1364/oe.15.007393 · Cited by 26
Enhanced visualization of oral cavity for early inflamed tissue detection
Wang, H., Chen, Y.-T., Lin, J., Chiang, C., & Cheng, F. (2010) · Optics Express · doi:10.1364/oe.18.011800 · Cited by 25
70 kHz full 4x4 Mueller polarimeter and simultaneous fiber calibration for endoscopic applications
Rivet, S., Bradu, A., & Podoleanu, A. G. (2015) · Optics Express · doi:10.1364/oe.23.023768 · Cited by 25
Blood Oxygen Saturation Measurement Using Polarization-Dependent Optical Sectioning
Mishra, D., Priyadarshini, N., Chakraborty, S., & Sarkar, M. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2698520 · Cited by 25
Fiber-optic device for endoscopic polarization imaging
Desroches, J., Pagnoux, D., Louradour, F., & Barthélémy, A. (2009) · Optics Letters · doi:10.1364/ol.34.003409 · Cited by 25
Effects of turbid media optical properties on object visibility in subsurface polarization imaging
Nothdurft, R. E., & Yao, G. (2006) · Applied Optics · doi:10.1364/ao.45.005532 · Cited by 25
Multispectral tissue characterization for intestinal anastomosis optimization
Cha, J., Shademan, A., Le, H. N. D., Decker, R., Kim, P. C. W., Kang, J. U., & Krieger, A. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.106001 · Cited by 24
Manhas, S. S., Swami, M. K., Buddhiwant, P., Ghosh, N., Gupta, P. K., & Singh, K. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.697294 · Cited by 24
A possible quantitative Mueller matrix transformation technique for anisotropic scattering media
Ma, H. (2013) · Cited by 24
Hanlon, K. (2018) · Journal of Visual Communication in Medicine · doi:10.1080/17453054.2018.1420418 · Cited by 24
Tuchin, V. V. (2014) · CRC Press eBooks · doi:10.1201/b17290-9 · Cited by 24
Handbook of Optical Biomedical Diagnostics, Second Edition, Volume 1: Light-Tissue Interaction
(2016) · SPIE eBooks · doi:10.1117/3.2219603 · Cited by 24
Probing layered structures by multi-color backscattering polarimetry and machine learning
Zhu, Y., Dong, Y., Yao, Y., Si, L., Liu, Y., He, H., & Ma, H. (2021) · Biomedical Optics Express · doi:10.1364/boe.425614 · Cited by 23
Light scattering from normal and cervical cancer cells
Lin, X., Wan, N., Weng, L., & Zhou, Y. H. (2017) · Applied Optics · doi:10.1364/ao.56.003608 · Cited by 23
Lindberg, A., Vizet, J., Rehbinder, J., Gennet, C., Vanel, J., & Pierangelo, A. (2019) · Applied Optics · doi:10.1364/ao.58.005187 · Cited by 24
Deep tissue sensing of chiral molecules using polarization-enhanced photoacoustics
Padmanabhan, S., & Prakash, J. (2025) · Science Advances · doi:10.1126/sciadv.ado8012 · Cited by 22
Polarization imaging-based radiomics approach for the staging of liver fibrosis
Yao, Y., Zhang, F., Wang, B., Wan, J., Si, L., Dong, Y., Zhu, Y., Liu, X., Chen, L., & Ma, H. (2022) · Biomedical Optics Express · doi:10.1364/boe.450294 · Cited by 22
Mueller matrix decomposition for biological tissue analysis
Martin, L., Brun, G. L., & Jeune, B. L. (2012) · Optics Communications · doi:10.1016/j.optcom.2012.11.086 · Cited by 22
Microscopy and Cell Biology: New Methods and New Questions
Morris, J. D., & Payne, C. K. (2019) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-042018-052527 · Cited by 23
Zhao, Y., Reda, M., Feng, K., Zhang, P., Cheng, G., Ren, Z., Kong, S. G., Su, S., Haixia, H., & Zang, J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2978021 · Cited by 22
Polarization-gated imaging in tissue phantoms: effect of size distribution
Shukla, P. K., & Pradhan, A. (2009) · Applied Optics · doi:10.1364/ao.48.006099 · Cited by 22
Gareau, D. S., Merlino, G. T., Corless, C. L., Kulesz-Martin, M. F., & Jacques, S. L. (2007) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700829 · Cited by 22
Self-citationSnapshot, reconfigurable multispectral and multi-polarization telecentric imaging system
Pacheco, S., & Liang, R. (2014) · Optics Express · doi:10.1364/oe.22.016377 · Cited by 21
A new approach for optical assessment of directional anisotropy in turbid media
Ghassemi, P., Moffatt, L. T., Shupp, J. W., & Ramella‐Roman, J. C. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400124 · Cited by 21
Self-citationJacques, S. L., Roussel, S., & Samatham, R. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071115 · Cited by 21
Self-citationZheng, F., Tao, X., Yang, M., Zhu, G., Jin, B., Kang, L., Xu, W., Chen, J., & Wu, P. (2016) · Journal of the Optical Society of America B · doi:10.1364/josab.33.002256 · Cited by 21
Holistic Monte-Carlo optical modelling of biological imaging
Carles, G., Zammit, P., & Harvey, A. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-51850-1 · Cited by 21
Liu, Y., Kim, Y. L., & Backman, V. (2005) · Applied Optics · doi:10.1364/ao.44.002288 · Cited by 21
Polarization-sensitive speckle spectroscopy of scattering media beyond the diffusion limit
Zimnyakov, D. A., Oh, J.-T., Sinichkin, Y. P., Trifonov, V. A., & Gurianov, E. V. (2004) · Journal of the Optical Society of America A · doi:10.1364/josaa.21.000059 · Cited by 21
Safrani, A., Aharon, O., Mor, S., Arnon, O., Rosenberg, L. A., & Abdulhalim, I. S. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3394338 · Cited by 20
Turbid medium polarimetry in biomedical imaging and diagnosis
Ghosh, N., Banerjee, A., & Soni, J. (2011) · The European Physical Journal Applied Physics · doi:10.1051/epjap/2011110017 · Cited by 20
Modeling low-coherence enhanced backscattering using Monte Carlo simulation
Subramanian, H., Pradhan, P., Kim, Y. L., Liu, Y., Li, X., & Backman, V. (2006) · Applied Optics · doi:10.1364/ao.45.006292 · Cited by 20
Optical assessment of tissue anisotropy in ex vivo distended rat bladders
Alali, S., AITKEN, K. J., Schröder, A., & Bägli, D. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.086010 · Cited by 18
Bashkatov, A. N., Genina, E. A., Tuchin, V. V., Altshuler, G. B., & Yaroslavsky, I. V. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.803909 · Cited by 19
Yakovlev, D. D., Евгеньевна, Ш. М., Sherman, M. M., Spivak, A. V., Pravdin, A. B., & Yakovlev, D. A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071111 · Cited by 19
Sun, P., Ma, Y., Liu, W., Xu, C., & Sun, X. (2013) · Journal of Optics · doi:10.1088/2040-8978/15/5/055708 · Cited by 19
Müller matrix polarimetry for pancreatic tissue characterization
Sampaio, P., Lopez-Antuña, M., Storni, F., Wicht, J., Sökeland, G., Wartenberg, M., Márquez-Neila, P., Candinas, D., Demory, B.-O., Perren, A. A., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-43195-7 · Cited by 16
Zaffar, M., & Pradhan, A. (2020) · Journal of Biophotonics · doi:10.1002/jbio.201960139 · Cited by 18
Feng, X. G., Patel, R., & Yaroslavsky, A. N. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400105 · Cited by 19
Aharon, O., Abdulhalim, I. S., Arnon, O., Rosenberg, L. A., Silberstein, E., & Dyomin, V. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3609003 · Cited by 18
Classification of skin moles from optical spectropolarimetric images: a pilot study
Graham, L., Yitzhak Yitzhaky, B., & Abdulhalim, I. S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.11.111403 · Cited by 18
Giakos, G. C., Valluru, K., Adya, V., Ambadipudi, K., Paturi, S., Bathini, P., Becker, M., Farajipour, P., Marotta, S., Paxitzis, J. T., et al. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104003 · Cited by 18
Li, X., Hu, H., Liu, T., Huang, B., & Song, Z. (2016) · Optics Express · doi:10.1364/oe.24.007191 · Cited by 18
Polarized laser Doppler perfusion imaging—reduction of movement-induced artifacts
Karlsson, D. M., & Wårdell, K. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2120467 · Cited by 18
Deng, H., Li‐Tsang, C. W. P., & Li, J. (2020) · Skin Research and Technology · doi:10.1111/srt.12812 · Cited by 17
Evolution of raw meat polarization‐based properties by means of Mueller matrix imaging
Peyvasteh, M., Popov, A., Bykov, A. V., Pierangelo, A., Novikova, T., & Meglinski, I. V. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000376 · Cited by 17
Metadata
- Authors
- Jacques, S. L., Ramella-Roman, J. C., & Lee, K.
- Affiliations
- Providence St. Vincent Medical Center (US)
- Oregon Health and Science Univ.
- Oregon Medical Laser Ctr.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2002-07-01
- Volume
- 7
- Issue
- 03
- Pages
- 329-340
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W2044515481
- Cited by
- 582
- References
- 24
- Citations by year
- 2026: 6 · 2025: 15 · 2024: 16 · 2023: 25 · 2022: 24 · 2021: 22 · 2020: 25 · 2019: 25 · 2018: 30 · 2017: 28 · 2016: 45 · 2015: 34 · 2014: 31 · 2013: 27 · 2012: 28
- FWCI
- 15.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca080985-03)
- National Cancer Institute (R01-CA84587, R01-CA80985)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Optical Polarization and Ellipsometry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Oncology › Cutaneous Melanoma Detection and Management
- Keywords
- polarization imaging, dermatopathology, collagen birefringence, polarization ratio, skin pigmentation, freckles, tattoos, pigmented nevi, neurofibroma, actinic keratosis, basal cell carcinoma, squamous cell carcinoma, venous lakes, burn scars, point spread function
- MeSH terms
- Adult, Biophysics, Burns, Basal Cell Carcinoma, Carcinoma, Basal Cell, Carcinoma, Squamous Cell, Cicatrix, Humans, Keratosis, Neurofibroma, Nevus, Pigmented, Pilot Projects, Scattering, Radiation, Skin, Skin Abnormalities, Skin Neoplasms, Optics and Photonics, Biophysical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review