The DOI matches its Crossref record.
Diagnosing breast cancer using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy
Open accessAbstract
Using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy, we have developed an algorithm that successfully classifies normal breast tissue, fibrocystic change, fibroadenoma, and infiltrating ductal carcinoma in terms of physically meaningful parameters. We acquire 202 spectra from 104 sites in freshly excised breast biopsies from 17 patients within 30 min of surgical excision. The broadband diffuse reflectance and fluorescence spectra are collected via a portable clinical spectrometer and specially designed optical fiber probe. The diffuse reflectance spectra are fit using modified diffusion theory to extract absorption and scattering tissue parameters. Intrinsic fluorescence spectra are extracted from the combined fluorescence and diffuse reflectance spectra and analyzed using multivariate curve resolution. Spectroscopy results are compared to pathology diagnoses, and diagnostic algorithms are developed based on parameters obtained via logistic regression with cross-validation. The sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy (total efficiency) of the algorithm are 100, 96, 69, 100, and 91%, respectively. All invasive breast cancer specimens are correctly diagnosed. The combination of diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy yields promising results for discrimination of breast cancer from benign breast lesions and warrants a prospective clinical study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Monte Carlo modeling of light transport in tissues
Zhu, C., & Liu, Q. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.050902 · Cited by 352
Nachabe, R., Hendriks, B. H., Lucassen, G. W., van der Voort, M., Evers, D. J., Rutgers, E. J., Peeters, M.-J. V., Van der Hage, J. A., Oldenburg, H. S., Ruers, T. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3611010 · Cited by 161
Metadata
- Authors
- Volynskaya, Z., Haka, A. S., Bechtel, K. L., Fitzmaurice, M., Shenk, R., Wang, N., Nazemi, J., Dasari, R. R., & Feld, M. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 2
- Pages
- 024012
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2099048264
- Cited by
- 202
- References
- 0
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnosing breast cancer using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy. https://app.cochat.ai/papers/10.1117/1.2909672
- The paper
- Volynskaya, Z., Haka, A. S., Bechtel, K. L., Fitzmaurice, M., Shenk, R., Wang, N., Nazemi, J., Dasari, R. R., & Feld, M. S. (2008). Diagnosing breast cancer using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy. Journal of Biomedical Optics. https://doi.org/10.1117/1.2909672
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.