Collagen fiber arrangement in normal and diseased cartilage studied by polarization sensitive nonlinear microscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Second harmonic generation (SHG) and two-photon fluorescence (TPF) microscopy is used to image the intercellular and pericellular matrix in normal and degenerate equine articular cartilage. The polarization sensitivity of SHG can be used directly to determine fiber orientation in the superficial 10 to 20 microm of tissue, and images of the ratio of intensities taken with two orthogonal polarization states reveal small scale variations in the collagen fiber organization that have not previously been reported. The signal from greater depths is influenced by the birefringence and biattenuance of the overlying tissue. An assessment of these effects is developed, based on the analysis of changes in TPF polarization with depth, and the approach is validated in tendon where composition is independent of depth. The analysis places an upper bound on the biattenuance of tendon of 2.65 x 10(-4). Normal cartilage reveals a consistent pattern of variation in fibril orientation with depth. In lesions, the pattern is severely disrupted and there are changes in the pericellular matrix, even at the periphery where the tissue appears microscopically normal. Quantification of polarization sensitivity changes with depth in cartilage will require detailed numerical models, but in the meantime, multiphoton microscopy provides sensitive indications of matrix changes in cartilage degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
Cited by
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Cartilage Tissue Engineering by the 3D Bioprinting of iPS Cells in a Nanocellulose/Alginate Bioink
Nguyen, D., Hägg, D. A., Forsman, A., Ekholm, J., Nimkingratana, P., Brantsing, C., Kalogeropoulos, T., Zaunz, S., Concaro, S., Brittberg, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00690-y · Cited by 484
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
“133 Chondrocytes contribute 5% of cartilage volume.”
BackgroundIn vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy
Latour, G., Gusachenko, I., Kowalczuk, L., Lamarre, I., & Schanne-Klein, M.-C. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000001 · Cited by 139
Collagen and mature elastic fibre organisation as a function of depth in the human cornea and limbus
Kamma-Lorger, C. S., Boote, C., Hayes, S., Moger, J., Burghammer, M., Knupp, C., Quantock, A. J., Sorensen, T., Di Cola, E., & White, N. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.11.004 · Cited by 66
Self-citation
Metadata
- Authors
- Mansfield, J. C., Winlove, C. P., Moger, J., & Matcher, S. J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 4
- Pages
- 044020
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1971156750
- Cited by
- 119
- References
- 1
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.