Cited by 139Advanced Fluorescence Microscopy TechniquesCorneal surgery and disordersSpectroscopy Techniques in Biomedical and Chemical Research

In vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy

Open access
Latour, Gaël, Gusachenko, Ivan, Kowalczuk, Laura, Lamarre, Isabelle, Schanne-Klein, Marie-Claire·2012·Biomedical Optics Express

Abstract

The transparency and mechanical strength of the cornea are related to the highly organized three-dimensional distribution of collagen fibrils. It is of great interest to develop specific and contrasted in vivo imaging tools to probe these collagenous structures, which is not available yet. Second Harmonic Generation (SHG) microscopy is a unique tool to reveal fibrillar collagen within unstained tissues, but backward SHG images of cornea fail to reveal any spatial features due to the nanometric diameter of stromal collagen fibrils. To overcome this limitation, we performed polarization-resolved SHG imaging, which is highly sensitive to the sub-micrometer distribution of anisotropic structures. Using advanced data processing, we successfully retrieved the orientation of the collagenous fibrils at each depth of human corneas, even in backward SHG homogenous images. Quantitative information was also obtained about the submicrometer heterogeneities of the fibrillar collagen distribution by measuring the SHG anisotropy. All these results were consistent with numerical simulation of the polarization-resolved SHG response of cornea. Finally, we performed in vivo SHG imaging of rat corneas and achieved structural imaging of corneal stroma without any labeling. Epi-detected polarization-resolved SHG imaging should extend to other organs and become a new diagnosis tool for collagen remodeling.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/boe.3.000001

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Second harmonic generation imaging can provide qualitative and quantitative information about lamellar organisation within the cornea and has the potential to be used in vivo.

    “Over the last decade there has been an upsurge in the use of non-linear microscopy, in particular second harmonic generation imaging, to provide qualitative (Han et al., 2005, Morishige et al., 2006, Teng et al., 2006, Bueno et al., 2011) and quantitative (Mega et al., 2012, Tuer et al., 2012, Ghazaryan et al., 2013) information about the lamellar organisation within the cornea, a technique that,”

    From Corneal structure and transparency (2015) · cites this paper as Latour et al., 2012

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 36

  1. [1]Guthoff R. F. Zhivov A. Stachs O., “ In vivo confocal microscopy, an inner vision of the cornea - a major review,” Clin. Experiment. Ophthalmol. 37(1), 100– 117 (2009). 10.1111/j.1442-9071.2009.02016.x 19338608 · DOI
  2. [2]Gora M. Karnowski K. Szkulmowski M. Kaluzny B. J. Huber R. Kowalczyk A. Wojtkowski M., “ Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range,” Opt. Express 17(17), 14880– 14894 (2009). 10.1364/OE.17.014880 19687967 · DOI
  3. [3]Latour G. Georges G. Lamoine L. S. Deumié C. Conrath J. Hoffart L., “ Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography,” J. Biomed. Opt. 15(5), 056006 (2010). 10.1117/1.3486544 21054100 · DOI
  4. [4]J. H. Krachmer, M. J. Mannis, and E. J. Holland, Cornea, 2nd ed. (Mosby, 2005).
  5. [5]Plamann K. Aptel F. Arnold C. L. Courjaud A. Crotti C. Deloison F. Druon F. Georges P. Hanna M. Legeais J.-M. Morin F. Mottay É. Nuzzo V. Peyrot D. A. Savoldelli M., “ Ultrashort pulse laser surgery of the cornea and the sclera,” J. Opt. 12(8), 084002 (2010). 10.1088/2040-8978/12/8/084002 · DOI
  6. [6]Hao M. Flynn K. Nien-Shy C. Jester B. E. Winkler M. Brown D. J. La Schiazza O. Bille J. Jester J. V., “ In vivo non-linear optical (NLO) imaging in live rabbit eyes using the Heidelberg Two-Photon Laser Ophthalmoscope,” Exp. Eye Res. 91(2), 308– 314 (2010). 10.1016/j.exer.2010.06.007 20558159 PMC2922943 · DOI
  7. [7]Campagnola P. J. Millard A. C. Terasaki M. Hoppe P. E. Malone C. J. Mohler W. A., “ Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues,” Biophys. J. 82(1), 493– 508 (2002). 10.1016/S0006-3495(02)75414-3 11751336 PMC1302489 · DOI
  8. [8]Zipfel W. R. Williams R. M. Christie R. Nikitin A. Y. Hyman B. T. Webb W. W., “ Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation,” Proc. Natl. Acad. Sci. U.S.A. 100(12), 7075– 7080 (2003). 10.1073/pnas.0832308100 12756303 PMC165832 · DOI
  9. [9]Piston D. W. Masters B. R. Webb W. W., “ Three-dimensionally resolved NAD(P)H cellular metabolic redox imaging of the in situ cornea with two-photon excitation laser scanning microscopy,” J. Microsc. 178(1), 20– 27 (1995). 10.1111/j.1365-2818.1995.tb03576.x 7745599 · DOI
  10. [10]Yeh A. T. Nassif N. Zoumi A. Tromberg B. J., “ Selective corneal imaging using combined second-harmonic generation and two-photon excited fluorescence,” Opt. Lett. 27(23), 2082– 2084 (2002). 10.1364/OL.27.002082 18033448 · DOI
  11. [11]Han M. Giese G. Bille J., “ Second harmonic generation imaging of collagen fibrils in cornea and sclera,” Opt. Express 13(15), 5791– 5797 (2005). 10.1364/OPEX.13.005791 19498583 · DOI · Paper page
  12. [12]Teng S.-W. Tan H.-Y. Peng J.-L. Lin H.-H. Kim K. H. Lo W. Sun Y. Lin W.-C. Lin S.-J. Jee S.-H. So P. T. C. Dong C.-Y., “ Multiphoton autofluorescence and second-harmonic generation imaging of the ex vivo porcine eye,” Invest. Ophthalmol. Vis. Sci. 47(3), 1216– 1224 (2006). 10.1167/iovs.04-1520 16505061 · DOI
  13. [13]Morishige N. Nishida T. Jester J. J., “ Second harmonic generation for visualizing 3-dimensional structure of corneal collagen lamellae,” Cornea 28(Suppl 1), S46– S53 (2009). 10.1097/ICO.0b013e3181ae9f37 · DOI
  14. [14]Matteini P. Ratto F. Rossi F. Cicchi R. Stringari C. Kapsokalyvas D. Pavone F. S. Pini R., “ Photothermally-induced disordered patterns of corneal collagen revealed by SHG imaging,” Opt. Express 17(6), 4868– 4878 (2009). 10.1364/OE.17.004868 19293918 · DOI
  15. [15]Aptel F. Olivier N. Deniset-Besseau A. Legeais J.-M. Plamann K. Schanne-Klein M.-C. Beaurepaire E., “ Multimodal nonlinear imaging of the human cornea,” Invest. Ophthalmol. Vis. Sci. 51(5), 2459– 2465 (2010). 10.1167/iovs.09-4586 20071677 · DOI
  16. [16]Olivier N. Aptel F. Plamann K. Schanne-Klein M.-C. Beaurepaire E., “ Harmonic microscopy of isotropic and anisotropic microstructure of the human cornea,” Opt. Express 18(5), 5028– 5040 (2010). 10.1364/OE.18.005028 20389515 · DOI
  17. [17]Bueno J. M. Gualda E. J. Giakoumaki A. Pérez-Merino P. Marcos S. Artal P., “ Multiphoton microscopy of ex vivo corneas after collagen cross-linking,” Invest. Ophthalmol. Vis. Sci. 52(8), 5325– 5331 (2011). 10.1167/iovs.11-7184 21467175 · DOI
  18. [18]Strupler M. Pena A.-M. Hernest M. Tharaux P.-L. Martin J.-L. Beaurepaire E. Schanne-Klein M.-C., “ Second harmonic imaging and scoring of collagen in fibrotic tissues,” Opt. Express 15(7), 4054– 4065 (2007). 10.1364/OE.15.004054 19532649 · DOI
  19. [19]Deniset-Besseau A. Duboisset J. Benichou E. Hache F. Brevet P.-F. Schanne-Klein M.-C., “ Measurement of the second-order hyperpolarizability of the collagen triple helix and determination of its physical origin,” J. Phys. Chem. B 113(40), 13437– 13445 (2009). 10.1021/jp9046837 19754079 · DOI
  20. [20]Lacomb R. Nadiarnykh O. Townsend S. S. Campagnola P. J., “ Phase Matching considerations in Second Harmonic Generation from tissues: Effects on emission directionality, conversion efficiency and observed morphology,” Opt. Commun. 281(7), 1823– 1832 (2008). 10.1016/j.optcom.2007.10.040 19343083 PMC2390911 · DOI
  21. [22]Rivard M. Laliberté M. Bertrand-Grenier A. Harnagea C. Pfeffer C. P. Vallières M. St-Pierre Y. Pignolet A. El Khakani M. A. Légaré F., “ The structural origin of second harmonic generation in fascia,” Biomed. Opt. Express 2(1), 26– 36 (2011). 10.1364/BOE.2.000026 21326632 PMC3028495 · DOI
  22. [23]Tiaho F. Recher G. Rouède D., “ Estimation of helical angles of myosin and collagen by second harmonic generation imaging microscopy,” Opt. Express 15(19), 12286– 12295 (2007). 10.1364/OE.15.012286 19547597 · DOI
  23. [24]Stoller P. Reiser K. M. Celliers P. M. Rubenchik A. M., “ Polarization-modulated second harmonic generation in collagen,” Biophys. J. 82(6), 3330– 3342 (2002). 10.1016/S0006-3495(02)75673-7 12023255 PMC1302120 · DOI
  24. [25]Nadiarnykh O. Campagnola P. J., “ Retention of polarization signatures in SHG microscopy of scattering tissues through optical clearing,” Opt. Express 17(7), 5794– 5806 (2009). 10.1364/OE.17.005794 19333348 PMC4487673 · DOI
  25. [26]Gusachenko I. Latour G. Schanne-Klein M.-C., “ Polarization-resolved Second Harmonic microscopy in anisotropic thick tissues,” Opt. Express 18(18), 19339– 19352 (2010). 10.1364/OE.18.019339 20940829 · DOI
  26. [27]Brasselet S. Aït-Belkacem D. Gasecka A. Munhoz F. Brustlein S. Brasselet S., “ Influence of birefringence on polarization resolved nonlinear microscopy and collagen SHG structural imaging,” Opt. Express 18(14), 14859– 14870 (2010). 10.1364/OE.18.014859 20639973 · DOI
  27. [28]Psilodimitrakopoulos S. Santos S. I. C. O. Amat-Roldan I. Thayil A. K. N. Artigas D. Loza-Alvarez P., “ In vivo, pixel-resolution mapping of thick filaments’ orientation in nonfibrilar muscle using polarization-sensitive second harmonic generation microscopy,” J. Biomed. Opt. 14(1), 014001 (2009). 10.1117/1.3059627 19256689 · DOI
  28. [29]Chen W.-L. Li T.-H. Su P.-J. Chou C.-K. Fwu P. T. Lin S.-J. Kim D. So P. T. C. Dong C.-Y., “ Second harmonic generation chi tensor microscopy for tissue imaging,” Appl. Phys. Lett. 94(18), 183902 (2009). 10.1063/1.3132062 · DOI
  29. [30]Nucciotti V. Stringari C. Sacconi L. Vanzi F. Fusi L. Linari M. Piazzesi G. Lombardi V. Pavone F. S., “ Probing myosin structural conformation in vivo by second-harmonic generation microscopy,” Proc. Natl. Acad. Sci. U.S.A. 107(17), 7763– 7768 (2010). 10.1073/pnas.0914782107 20385845 PMC2867856 · DOI
  30. [31]Plotnikov S. V. Millard A. C. Campagnola P. J. Mohler W. A., “ Characterization of the myosin-based source for second-harmonic generation from muscle sarcomeres,” Biophys. J. 90(2), 693– 703 (2006). 10.1529/biophysj.105.071555 16258040 PMC1367074 · DOI
  31. [33]Réfrégier P. Roche M. Brasselet S., “ Precision analysis in polarization-resolved second harmonic generation microscopy,” Opt. Lett. 36(11), 2149– 2151 (2011). 10.1364/OL.36.002149 21633478 · DOI
  32. [34]Mansfield J. C. Winlove C. P. Moger J. Matcher S. J., “ Collagen fiber arrangement in normal and diseased cartilage studied by polarization sensitive nonlinear microscopy,” J. Biomed. Opt. 13(4), 044020 (2008). 10.1117/1.2950318 19021348 · DOI
  33. [35]L. J. Bour, “Polarized light and the eye” in Visual Optics and Instrumentation, W. N. Charman, ed. (CRC Press,1991), Vol. 1, Chap. 13.
  34. [36]L. Novotny and B. Hecht, Principles of Nano-Optics (Cambridge University Press, 2006).
  35. [37]Radner W. Zehetmayer M. Aufreiter R. Mallinger R., “ Interlacing and cross-angle distribution of collagen lamellae in the human cornea,” Cornea 17(5), 537– 543 (1998). 10.1097/00003226-199809000-00012 9756449 · DOI · Paper page
  36. [38]Allgeier S. Zhivov A. Eberle F. Koehler B. Maier S. Bretthauer G. Guthoff R. F. Stachs O., “ Image reconstruction of the subbasal nerve plexus with in vivo confocal microscopy,” Invest. Ophthalmol. Vis. Sci. 52(9), 5022– 5028 (2011). 10.1167/iovs.10-6065 21447691 · DOI

Cited by

Sorted by citations

Authors
Latour, G., Gusachenko, I., Kowalczuk, L., Lamarre, I., & Schanne-Klein, M.-C.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
Biomedical Optics Express
Published
2011-12-01
Volume
3
Issue
1
Pages
1
ISSN
2156-7085 (ISSN-L)
OpenAlex
W2105148077
Cited by
139
References
0
Citations by year
2026: 3 · 2025: 7 · 2024: 6 · 2023: 15 · 2022: 8 · 2021: 10 · 2020: 8 · 2019: 8 · 2018: 7 · 2017: 9 · 2016: 9 · 2015: 16 · 2014: 12 · 2013: 12 · 2012: 9
FWCI
5.79
Type
journal article
Language
en
Open access
Locations
  • Biomedical Optics Express (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
  • Agence Nationale de la Recherche
  • Fondation de France
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
cornea, collagen fibrils, polarization-resolved second harmonic generation, second harmonic generation microscopy, collagen orientation, corneal stroma, in vivo imaging, label-free imaging, collagen remodeling, rat cornea

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review