The DOI matches its Crossref record.
Diagnosing breast cancer using Raman spectroscopy: prospective analysis
Open accessAbstract
We present the first prospective test of Raman spectroscopy in diagnosing normal, benign, and malignant human breast tissues. Prospective testing of spectral diagnostic algorithms allows clinicians to accurately assess the diagnostic information contained in, and any bias of, the spectroscopic measurement. In previous work, we developed an accurate, internally validated algorithm for breast cancer diagnosis based on analysis of Raman spectra acquired from fresh-frozen in vitro tissue samples. We currently evaluate the performance of this algorithm prospectively on a large ex vivo clinical data set that closely mimics the in vivo environment. Spectroscopic data were collected from freshly excised surgical specimens, and 129 tissue sites from 21 patients were examined. Prospective application of the algorithm to the clinical data set resulted in a sensitivity of 83%, a specificity of 93%, a positive predictive value of 36%, and a negative predictive value of 99% for distinguishing cancerous from normal and benign tissues. The performance of the algorithm in different patient populations is discussed. Sources of bias in the in vitro calibration and ex vivo prospective data sets, including disease prevalence and disease spectrum, are examined and analytical methods for comparison provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman Spectroscopy of Biological Tissues
Talari, A. C. S., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.923902 · Cited by 739
Kong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Using single-vesicle technologies to unravel the heterogeneity of extracellular vesicles
Bordanaba-Florit, G., Royo, F., Kruglik, S. G., & Falcón-Pérez, J. M. (2021) · Nature Protocols · doi:10.1038/s41596-021-00551-z · Cited by 325
Analysis of cholesterol trafficking with fluorescent probes
Maxfield, F. R., & Wüstner, D. (2012) · Methods in Cell Biology · doi:10.1016/b978-0-12-386487-1.00017-1 · Cited by 240
Metadata
- Authors
- Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Shenk, R., Wang, N., Dasari, R. R., Fitzmaurice, M., & Feld, M. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2009
- Volume
- 14
- Issue
- 5
- Pages
- 054023
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2151627869
- Cited by
- 193
- References
- 0
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnosing breast cancer using Raman spectroscopy: prospective analysis. https://app.cochat.ai/papers/10.1117/1.3247154
- The paper
- Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Shenk, R., Wang, N., Dasari, R. R., Fitzmaurice, M., & Feld, M. S. (2009). Diagnosing breast cancer using Raman spectroscopy: prospective analysis. Journal of Biomedical Optics. https://doi.org/10.1117/1.3247154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.