CoChat

Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions

Open access

The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.

Abstract

We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman±2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within±2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.3309746

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?" Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.

Cited by

Metadata

Authors
Muthalib, M., Millet, G. Y., Quaresima, V., & Nosaka, K.
Affiliations
  • Edith Cowan University (AU)
  • University of L'Aquila (IT)
Venue
Journal of Biomedical Optics
Published
2010-01-01
Volume
15
Issue
01
Pages
1-8
ISSN
  • 1083-3668 (ISSN-L)
  • 1560-2281
OpenAlex
W2005023133
Cited by
71
References
25
Citations by year
2025: 7 · 2024: 5 · 2023: 1 · 2022: 6 · 2021: 4 · 2020: 5 · 2019: 4 · 2018: 13 · 2017: 2 · 2016: 5 · 2015: 4 · 2014: 2 · 2013: 1 · 2012: 4
FWCI
3.38
Type
journal article
Language
en
Open access
Locations
  • Journal of Biomedical Optics (publishedVersion)
  • PubMed (publishedVersion)
  • Figshare (submittedVersion, cc-by)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
near-infrared spectroscopy, biceps brachii, tissue oxygenation index, test-retest reliability, isometric contraction, sustained contraction, repeated contractions, muscle oxygenation, muscle torque, maximal voluntary contraction, coefficient of variation
MeSH terms
Adult, Analysis of Variance, Humans, Isometric Contraction, Male, Oxygen, Reproducibility of Results, Muscle, Skeletal, Spectroscopy, Near-Infrared, Torque

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.