Assessment of liver steatosis and fibrosis in rats using integrated coherent anti-Stokes Raman scattering and multiphoton imaging technique
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report the implementation of a unique integrated coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), and two-photon excitation fluorescence (TPEF) microscopy imaging technique developed for label-free monitoring of the progression of liver steatosis and fibrosis generated in a bile duct ligation (BDL) rat model. Among the 21 adult rats used in this study, 18 rats were performed with BDL surgery and sacrificed each week from weeks 1 to 6 (n = 3 per week), respectively; whereas 3 rats as control were sacrificed at week 0. Colocalized imaging of the aggregated hepatic fats, collagen fibrils, and hepatocyte morphologies in liver tissue is realized by using the integrated CARS, SHG, and TPEF technique. The results show that there are significant accumulations of hepatic lipid droplets and collagen fibrils associated with severe hepatocyte necrosis in BDL rat liver as compared to a normal liver tissue. The volume of normal hepatocytes keeps decreasing and the fiber collagen content in BDL rat liver follows a growing trend until week 6; whereas the hepatic fat content reaches a maximum in week 4 and then appears to stop growing in week 6, indicating that liver steatosis and fibrosis induced in a BDL rat liver model may develop at different rates. This work demonstrates that the integrated CARS and multiphoton microscopy imaging technique has the potential to provide an effective means for early diagnosis and detection of liver steatosis and fibrosis without labeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bataller, R., & Brenner, D. A. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24282 · Cited by 4,958
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“20 The major absorption in liver tissues arises from hemoglobin because of the widely distributed liver vasculature systems.”
BackgroundXu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198 · cited 1×
“16,17 One notes that the TPEF signal does not interfere with SHG imaging, as the 450-to 700-nm bandpass filter is used for TPEF, while the 415-nm bandpass filter (FWHM 10 nm) for SHG blocks the emission of major fluorophores in liver tissue [e.g., NADH and FAD (emission peaks are around 465 and 540…”
BackgroundChemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957 · cited 1×
“This probing depth is much shallower than that in the mouse ear’s skin (125 μ m) 19 probably due to a one-fold higher absorption coefficient in liver tissue as compared to skin tissues.”
Background
Cited by
A human multi-lineage hepatic organoid model for liver fibrosis
Guan, Y., Enejder, A., Wang, M., Fang, Z., Cui, L., Chen, S.-Y., Wang, J., Tan, Y., Wu, M., Chen, X., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26410-9 · Cited by 149
Gieseck, R. L., Ramalingam, T. R., Hart, K. M., Vannella, K. M., Cantu, D. A., Lu, W.-Y., Ferreira-González, S., Forbes, S. J., Vallier, L., & Wynn, T. A. (2016) · Immunity · doi:10.1016/j.immuni.2016.06.009 · Cited by 132
“These findings are consistent with the steatosis that develops in rats during experimental bile duct ligation (Lin et al., 2011) and in human patients with extrahepatic cholestasis”
Spaceflight Activates Lipotoxic Pathways in Mouse Liver
Jonscher, K. R., Alfonso-Garcia, A., Suhalim, J. L., Orlicky, D. J., Potma, E. O., Ferguson, V. L., Bouxsein, M. L., Bateman, T. A., Stodieck, L. S., Levi, M., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152877 · Cited by 108
Metadata
- Authors
- Lin, J., Lu, F., Zheng, W., Huang, Z., Xu, S., Tai, D. C., & Yu, H.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2011-11-01
- Volume
- 16
- Issue
- 11
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2123493739
- Cited by
- 70
- References
- 4
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.