The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Light propagation in tissues with controlled optical properties
Open accessAbstract
Theoretical and computer modeling approaches, such as Mie theory, radiative transfer theory, diffusion wave correlation spectroscopy, and Monte Carlo simulation were used to analyze tissue optics during a process of optical clearing due to refractive index matching. Continuous wave transmittance and forward scattering measurements as well as intensity correlation experiments were used to monitor tissue structural and optical properties. As a control, tissue samples of the human sclera were taken. Osmotically active solutions, such as Trazograph, glucose, and polyethylene glycol, were used as chemicals. A characteristic time response of human scleral optical clearing the range 3 to 10 min was determined. The diffusion coefficients describing the permeability of the scleral samples to Trazograph were experimentally estimated; the average value was DT'(0.960.5)31025 cm2/s. The results are general and can be used to describe many other fibrous tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Absorption and Scattering of Light by Small Particles
Brown, R. G. W. (1984) · Optica Acta: International Journal of Optics · doi:10.1080/716099663 · Cited by 6,612
(1991) · PubMed · Cited by 678
Image Transfer Through a Scattering Medium
Zege, E. P., Ivanov, A. P., & Katsev, I. L. (1991) · Springer eBooks · doi:10.1007/978-3-642-75286-5 · Cited by 336
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Hammer, M., Roggan, A., Schweitzer, D., & Muller, G. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/6/001 · Cited by 247
Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Influence of glucose concentration on light scattering in tissue-simulating phantoms
Kohl, M., Essenpreis, M., Böcker, D., & Cope, M. (1994) · Optics Letters · doi:10.1364/ol.19.002170 · Cited by 158
The transparency of the mammalian cornea
Cox, J., Farrell, R. A., Hart, R. W., & Langham, M. E. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009230 · Cited by 145
Wang, X., Milner, T. E., Chang, M., & Nelson, J. S. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227699 · Cited by 87
Cited by
Tissue clearing of both hard and soft tissue organs with the PEGASOS method
Jing, D., Zhang, S., Luo, W., Gao, X., Men, Y., Ma, C., Liu, X., Yi, Y., Bugde, A., Zhou, B. O., et al. (2018) · Cell Research · doi:10.1038/s41422-018-0049-z · Cited by 394
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Self-citation
Metadata
- Authors
- Tuchin, V. V.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1997
- Volume
- 2
- Issue
- 4
- Pages
- 401
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2003025357
- Cited by
- 411
- References
- 20
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Light propagation in tissues with controlled optical properties. https://app.cochat.ai/papers/10.1117/1.429841
- The paper
- Tuchin, V. V. (1997). Light propagation in tissues with controlled optical properties. Journal of Biomedical Optics. https://doi.org/10.1117/1.429841
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.