CoChat

Oxygen supply-consumption balance in the thigh muscles during exhausting knee-extension exercise

Open access
Azuma, K., Homma, S., Kagaya, A. · 2000 · Journal of Biomedical Optics
Cited by 37

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to investigate the difference in muscle oxygenation between the individual muscles involved in an exhaustive knee-extension exercise. Eight active women performed exercise by extending the knee joint from 90 degrees to 30 degrees (60 extensions min-1) at 20%, 30%, and 40% maximum voluntary contraction (MVC). Changes in oxy-(delta HbO2), deoxy-(delta Hb), and total (delta HbT) hemoglobin concentrations, and oxygen saturation (delta SO2NIRS = HbO2/HbT) in the vastus lateralis (VL) and rectus femoris (RF) muscles were measured with a spatially resolved near-infrared spectrometer (NIRS). The delta SO2NIRS in the VL and RF decreased rapidly from the pre-exercise control value (VL: 75.6 +/- 0.9%; RF: 81.6 +/- 1.6%) at the onset of exercise at three different intensities, although no significant difference in delta SO2NIRS was found between the two muscles at this time. However, the delta SO2NIRS decreased more rapidly thereafter and reached a lower value at exhaustion in the VL than in the RF. The difference in delta SO2NIRS between the VL (-10.3 +/- 1.7%) and RF (-4.0 +/- 1.0%) was significant (p < 0.05) when exercise intensity was 30% MVC. When the decreases in delta HbO2 and delta HbT (p < 0.05) were compared at different exercise intensities, the values at 30% and 40% MVC were significantly lower (delta HbO2: p < 0.01; delta HbT: p < 0.05) than those at 20% MVC in the VL, but there was no significant difference in any of the parameters in the RF, or in delta Hb in the VL. These results suggest that the muscle oxidative response to exhaustive knee-extension exercise differed between the VL and RF muscles. At exhaustion, oxygen saturation decreased to a lower level in the VL than in the RF, and an intensity-dependent difference in muscle oxygenation parameters was observed at 30% MVC in the VL but not in the RF muscles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.429974

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Azuma, K., Homma, S., & Kagaya, A.
Venue
Journal of Biomedical Optics
Published
2000
Volume
5
Issue
1
Pages
97
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2049862543
Cited by
37
References
5
FWCI
2.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.