Spatial frequency domain tomography of protoporphyrin IX fluorescence in preclinical glioma models
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multifrequency (0 to 0.3 mm(-1)), multiwavelength (633, 680, 720, 800, and 820 nm) spatial frequency domain imaging (SFDI) of 5-aminolevulinic acid-induced protoporphyrin IX (PpIX) was used to recover absorption, scattering, and fluorescence properties of glioblastoma multiforme spheroids in tissue-simulating phantoms and in vivo in a mouse model. Three-dimensional tomographic reconstructions of the frequency-dependent remitted light localized the depths of the spheroids within 500 μm, and the total amount of PpIX in the reconstructed images was constant to within 30% when spheroid depth was varied. In vivo tumor-to-normal contrast was greater than ∼1.5 in reduced scattering coefficient for all wavelengths and was ∼1.3 for the tissue concentration of deoxyhemoglobin (ctHb). The study demonstrates the feasibility of SFDI for providing enhanced image guidance during surgical resection of brain tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423 · cited 1×
“4,5 Methods to quantify PpIX concentration in tissue using a fiber-optic “ point ” probe and a spectrally constrained model of light propagation have been shown to improve tumor detection with enhanced accuracy (87”
Method
Cited by
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Self-citation5‐ALA in the management of malignant glioma
Stepp, H., & Stummer, W. (2018) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22933 · Cited by 234
Saager, R. B., Balu, M., Crosignani, V., Sharif, A., Durkin, A. J., Kelly, K. M., & Tromberg, B. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.6.066005 · Cited by 76
Self-citationVisualization technologies for 5-ALA-based fluorescence-guided surgeries
Wei, L., Roberts, D. W., Sanai, N., & Liu, J. T. C. (2019) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-03077-9 · Cited by 67
Self-citation
Metadata
- Authors
- Konecky, S. D., Owen, C. M., Rice, T., Valdés, P. A., Kolste, K., Wilson, B. C., Leblond, F., Roberts, D. W., Paulsen, K. D., & Tromberg, B. J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012
- Volume
- 17
- Issue
- 5
- Pages
- 056008
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2163828524
- Cited by
- 65
- References
- 1
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial frequency domain tomography of protoporphyrin IX fluorescence in preclinical glioma models. https://app.cochat.ai/papers/10.1117/1.jbo.17.5.056008
- The paper
- Konecky, S. D., Owen, C. M., Rice, T., Valdés, P. A., Kolste, K., Wilson, B. C., Leblond, F., Roberts, D. W., Paulsen, K. D., & Tromberg, B. J. (2012). Spatial frequency domain tomography of protoporphyrin IX fluorescence in preclinical glioma models. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.17.5.056008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.