Review of speckle and phase variance optical coherence tomography to visualize microvascular networks
Open accessThe DOI matches its Crossref record.
Abstract
High-resolution mapping of microvasculature has been applied to diverse body systems, including the retinal and choroidal vasculature, cardiac vasculature, the central nervous system, and various tumor models. Many imaging techniques have been developed to address specific research questions, and each has its own merits and drawbacks. Understanding, optimization, and proper implementation of these imaging techniques can significantly improve the data obtained along the spectrum of unique research projects to obtain diagnostic clinical information. We describe the recently developed algorithms and applications of two general classes of microvascular imaging techniques: speckle-variance and phase-variance optical coherence tomography (OCT). We compare and contrast their performance with Doppler OCT and optical microangiography. In addition, we highlight ongoing work in the development of variance-based techniques to further refine the characterization of microvascular networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
Zhang, A., Zhang, Q., & Wang, R. K. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004130 · Cited by 173
Improved Angiogenesis in Response to Localized Delivery of Macrophage-Recruiting Molecules
Hsu, C.-W., Poché, R. A., Saik, J. E., Ali, S., Wang, S., Yosef, N., Calderon, G. A., Scott, L., Vadakkan, T. J., Larina, I. V., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131643 · Cited by 56
“These variations can be computed to produce image contrast, providing an image map of perfused vessels in 3D without using any external contrast agent [53,55].”
Background
Metadata
- Authors
- Mahmud, M. S., Cadotte, D. W., Vuong, B., Sun, C., Luk, T. W. H., Mariampillai, A., & Yang, V. X. D.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-04-24
- Volume
- 18
- Issue
- 5
- Pages
- 050901
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2045207186
- Cited by
- 213
- References
- 0
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of speckle and phase variance optical coherence tomography to visualize microvascular networks. https://app.cochat.ai/papers/10.1117/1.jbo.18.5.050901
- The paper
- Mahmud, M. S., Cadotte, D. W., Vuong, B., Sun, C., Luk, T. W. H., Mariampillai, A., & Yang, V. X. D. (2013). Review of speckle and phase variance optical coherence tomography to visualize microvascular networks. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.18.5.050901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.