The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Augmented reality for point-of-care ultrasound-guided vascular access in pediatric patients using Microsoft HoloLens 2: a preliminary evaluation
Open accessAbstract
SignificanceConventional ultrasound-guided vascular access procedures are challenging due to the need for anatomical understanding, precise needle manipulation, and hand–eye coordination. Recently, augmented reality (AR)-based guidance has emerged as an aid to improve procedural efficiency and potential outcomes. However, its application in pediatric vascular access has not been comprehensively evaluated.AimWe developed an AR ultrasound application, HoloUS, using the Microsoft HoloLens 2 to display live ultrasound images directly in the proceduralist’s field of view. We presented our evaluation of the effect of using the Microsoft HoloLens 2 for point-of-care ultrasound (POCUS)-guided vascular access in 30 pediatric patients.ApproachA custom software module was developed on a tablet capable of capturing the moving ultrasound image from any ultrasound machine’s screen. The captured image was compressed and sent to the HoloLens 2 via a hotspot without needing Internet access. On the HoloLens 2, we developed a custom software module to receive, decompress, and display the live ultrasound image. Hand gesture and voice command features were implemented for the user to reposition, resize, and change the gain and the contrast of the image. We evaluated 30 (15 successful control and 12 successful interventional) cases completed in a single-center, prospective, randomized study.ResultsThe mean overall rendering latency and the rendering frame rate of the HoloUS application were 139.30 ms (σ=32.02 ms) and 30 frames per second, respectively. The average procedure completion time was 17.3% shorter using AR guidance. The numbers of puncture attempts and needle redirections were similar between the two groups, and the number of head adjustments was minimal in the interventional group.ConclusionWe presented our evaluation of the results from the first study using the Microsoft HoloLens 2 that investigates AR-based POCUS-guided vascular access in pediatric patients. Our evaluation confirmed clinical feasibility and potential improvement in procedural efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“This systematic review and meta-analysis followed the PRISMA guidelines (Table S1) [2].”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [2]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The prevalence of DVA varies significantly, with rates between 10 and 26% in general hospitalized populations [1,2,6] and up to 60% in specialized populations [6,7] such as intensive care patients, those receiving chemotherapy, and individuals with chronic conditions.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [2]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research
(1988) · Advances in Psychology · doi:10.1016/s0166-4115(08)62386-9 · Cited by 15,003
NASA-Task Load Index (NASA-TLX); 20 Years Later
Hart, S. G. (2006) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120605000909 · Cited by 4,297
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 423
Evaluation of HoloLens Tracking and Depth Sensing for Indoor Mapping Applications
Hübner, P., Clintworth, K., Liu, Q., Martin Weinmann, A., & Wursthorn, S. (2020) · Sensors · doi:10.3390/s20041021 · Cited by 151
Managing complexity in the operating room: a group interview study
Göras, C., Nilsson, U. G., Ekstedt, M., Unbeck, M., & Ehrenberg, A. (2020) · BMC Health Services Research · doi:10.1186/s12913-020-05192-8 · Cited by 143
Measurement Invariance of the Nasa TLX
Bustamante, E. A., & Spain, R. D. (2008) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120805201946 · Cited by 81
Selection and Insertion of Vascular Access Devices in Pediatrics: A Systematic Review
Paterson, R., Chopra, V., Brown, E. A., Kleidon, T. M., Cooke, M. L., Rickard, C. M., Bernstein, S. J., & Ullman, A. J. (2020) · PEDIATRICS · doi:10.1542/peds.2019-3474h · Cited by 81
Scott-Warren, V., & Morley, R. (2014) · BJA Education · doi:10.1093/bjaceaccp/mku050 · Cited by 76
Naik, V. M., Mantha, S. P., & Rayani, B. K. (2019) · Indian Journal of Anaesthesia · doi:10.4103/ija.ija_489_19 · Cited by 72
Ultrasound-Guided Central Venous Access Using Google Glass
Wu, T. S., Dameff, C. J., & Tully, J. L. (2014) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2014.07.045 · Cited by 66
Subcutaneous Nitroglycerin for Radial Arterial Catheterization in Pediatric Patients
Jang, Y., Ji, S., Kim, E., Lee, J., Kim, H., Mossad, E. B., & Kim, J. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003308 · Cited by 46
Smart Glasses for Radial Arterial Catheterization in Pediatric Patients: A Randomized Clinical Trial
Jang, Y., Cho, S., Ji, S., Kim, E., Lee, J., Kim, H., & Kim, J. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003914 · Cited by 43
Saruwatari, M., Nguyen, T., Talari, H. F., Matisoff, A., Sharma, K. V., Donoho, K., Basu, S., Dwivedi, P., Bost, J. E., & Shekhar, R. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.07.011 · Cited by 32
Self-citationLehmann, J., & Seufert, T. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02820 · Cited by 20
Lim, H., Kim, M. J., Park, J. M., Kim, K. H., Park, J., Shin, D. W., Kim, H., Jeon, W., Kim, H., & Kim, J. E. (2019) · Clinical and Experimental Emergency Medicine · doi:10.15441/ceem.19.029 · Cited by 19
Suzuki, K., Morita, S., Endo, K., Yamamoto, T., Fujii, S., Ohya, J., Masamune, K., & Sakai, S. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02365-6 · Cited by 19
Color Rendering in Medical Extended-Reality Applications
Kim, A. S., Cheng, W., Beams, R., & Badano, A. G. (2020) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-020-00392-4 · Cited by 16
HoloLens 2 Sensor StreamingPreprint
Dibene, J. C., & Dunn, E. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2211.02648 · Cited by 9
Przkora, R., Mora, J., Balduyeu, P., Meroney, M., Vasilopoulos, T., & Solanki, D. R. (2020) · Pain Physician · doi:10.36076/ppj.2021.24.83-87 · Cited by 9
Zhao, C., Beams, R., Johnson, M., & Badano, A. G. (2022) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.15451 · Cited by 6
Templet, T. A., Rholdon, R. D., & Bienvenu, A. (2021) · Journal of Pediatric Intensive Care · doi:10.1055/s-0041-1736551 · Cited by 1
Cited by
Sorted by citations
Ghosn, Y., Schefflein, J., Jabbour, Y., Sarkar, D., & Cornélis, F. (2025) · Journal of Medical Extended Reality · doi:10.1177/29941520251377069 · Cited by 5
Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis
Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B. (2026) · Medicina · doi:10.3390/medicina62030604 · Cited by 2
Saliba, T., Rotzinger, D. C., & Gullo, G. (2026) · Radiological Physics and Technology · doi:10.1007/s12194-026-01035-z · Cited by 1
Hou, J. F., Viswanath, S., Dilibal, C., Wu, B., Shende, T., & Dağdeviren, C. (2026) · Communications Engineering · doi:10.1038/s44172-026-00692-7 · Cited by 1
Virtual Reality in Procedural Learning: An Underutilized Toolbox in Medical Education
Holloway, J. O., Yee, J. C., Holliday, S. A., & Essandoh, M. K. (2024) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2024.11.027
Metadata
- Authors
- Zhang, G., Nguyen, T. N., Fooladi-Talari, H., Salvador, T., Thomas, K., Crowley, D., Dingeman, R. S., & Shekhar, R.
- Affiliations
- Children's National (US)
- AusculTech Dx LLC
- Children's National Health System
- Venue
- Journal of Medical Imaging
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2024-09-13
- Volume
- 11
- Issue
- 06
- Pages
- 1-15
- ISSN
- 2329-4302 (ISSN-L)
- 2329-4310
- PMC
- PMC11393663
- OpenAlex
- W4402524555
- Semantic Scholar
- 50070386ad18a2a0e12739445e1c8a03224e6757
- Cited by
- 7
- References
- 21
- Citations by year
- 2026: 5 · 2025: 1 · 2024: 1
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- green
- pmc.ncbi.nlm.nih.gov
- Locations
- Journal of medical imaging (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Augmented Reality Applications
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Keywords
- augmented reality, point-of-care ultrasound, ultrasound-guided vascular access, pediatric patients, HoloLens 2, procedural efficiency, needle redirection, puncture attempts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review