Establishing the diffuse correlation spectroscopy signal relationship with blood flow
Open accessThe DOI matches its Crossref record.
Abstract
Diffuse correlation spectroscopy (DCS) measurements of blood flow rely on the sensitivity of the temporal autocorrelation function of diffusively scattered light to red blood cell (RBC) mean square displacement (MSD). For RBCs flowing with convective velocity [Formula: see text], the autocorrelation is expected to decay exponentially with [Formula: see text], where [Formula: see text] is the delay time. RBCs also experience shear-induced diffusion with a diffusion coefficient [Formula: see text] and an MSD of [Formula: see text]. Surprisingly, experimental data primarily reflect diffusive behavior. To provide quantitative estimates of the relative contributions of convective and diffusive movements, we performed Monte Carlo simulations of light scattering through tissue of varying vessel densities. We assumed laminar vessel flow profiles and accounted for shear-induced diffusion effects. In agreement with experimental data, we found that diffusive motion dominates the correlation decay for typical DCS measurement parameters. Furthermore, our model offers a quantitative relationship between the RBC diffusion coefficient and absolute tissue blood flow. We thus offer, for the first time, theoretical support for the empirically accepted ability of the DCS blood flow index ([Formula: see text]) to quantify tissue perfusion. We find [Formula: see text] to be linearly proportional to blood flow, but with a proportionality modulated by the hemoglobin concentration and the average blood vessel diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
Self-citationDynamic light scattering imaging
Postnov, D. D., Tang, J., Erdener, S. E., Kılıç, K., & Boas, D. A. (2020) · Science Advances · doi:10.1126/sciadv.abc4628 · Cited by 159
Self-citationFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Self-citationAjmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79
Impact of cutaneous blood flow on NIR-DCS measures of skeletal muscle blood flow index
Bartlett, M. F., Akins, J. D., Oneglia, A. P., Brothers, R. M., Wilkes, D., & Nelson, M. D. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00337.2021 · Cited by 9
Metadata
- Authors
- Boas, D. A., Sakadžic, S., Selb, J., Farzam, P., Franceschini, M. A., & Carp, S. A.
- Venue
- Neurophotonics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2016-06-13
- Volume
- 3
- Issue
- 3
- Pages
- 031412
- ISSN
- 2329-423X (ISSN-L)
- OpenAlex
- W2410095506
- Cited by
- 181
- References
- 0
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishing the diffuse correlation spectroscopy signal relationship with blood flow. https://app.cochat.ai/papers/10.1117/1.nph.3.3.031412
- The paper
- Boas, D. A., Sakadžic, S., Selb, J., Farzam, P., Franceschini, M. A., & Carp, S. A. (2016). Establishing the diffuse correlation spectroscopy signal relationship with blood flow. Neurophotonics. https://doi.org/10.1117/1.nph.3.3.031412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.