Dynamic light scattering imaging
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Nature of red blood cell dynamics and light scattering interactions unraveled to accurately probe cerebral blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: With Applications to Chemistry, Biology, and Physics
Berne, B. J., & Pecora, R. (1976) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,856
Pathophysiology and treatment of focal cerebral ischemia: Part I: Pathophysiology
Siesjö, B. K. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.2.0169 · Cited by 1,295
Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214
Self-citationPine, D. J., Weitz, D. A., Chaikin, P. M., & Herbolzheimer, E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1134 · Cited by 1,162
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122 · cited 8×
“where is the time lag, and reflects the effects of the source coherence properties and the spatial (1, 16, 18) and temporal averaging of the speckle dynamics.”
InfluentialSelf-citationModel for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836 · cited 14×
“The latter can be quantitatively related to the dynamics of the light scattering particles including flowing red blood cells (7, 8).”
InfluentialFunctional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
Pecora, R. (2011) · Medical Entomology and Zoology · Cited by 674
Flow visualization by means of single-exposure speckle photography
Fercher, A. F., & Briers, J. D. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90428-4 · Cited by 670 · cited 7×
“The latter can be quantitatively related to the dynamics of the light scattering particles including flowing red blood cells (7, 8).”
Influential
Cited by
Bian, S., Zheng, X., Liu, W., Li, J., Gao, Z., Ren, H., Zhang, W., Lee, C.-S., & Wang, P. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122130 · Cited by 29
Metadata
- Authors
- Postnov, D. D., Tang, J., Erdener, S. E., Kılıç, K., & Boas, D. A.
- Venue
- Science Advances
- Published
- 2020-11-06
- Volume
- 6
- Issue
- 45
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W3096590756
- Cited by
- 159
- References
- 47
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic light scattering imaging. https://app.cochat.ai/papers/10.1126/sciadv.abc4628
- The paper
- Postnov, D. D., Tang, J., Erdener, S. E., Kılıç, K., & Boas, D. A. (2020). Dynamic light scattering imaging. Science Advances. https://doi.org/10.1126/sciadv.abc4628
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.