The DOI matches its Crossref record.
New approach to 3-D registration of multimodality medical images by surface matching:
Abstract
Multimodality images obtained from medical imaging systems such as computed tomography (CT), magnetic resonance (MR) imaging, positron emission tomography (PET), and single photon emission computed tomography (SPECT), generally provide complementary characteristic and diagnostic information. Synthesis of these image data sets into a single composite image containing these complementary attributes in accurate registration and congruence would provide truly synergistic information about the object(s) under examination. We have developed a new method which produces such correlation using parametric Chamfer matching. The method is fast, accurate, and reproducible. Surfaces ar initially extracted from two different images to be matched using semi-automatic segmentation techniques. These surfaces are represented as contours with common features to be matched. A distance transformation is performed for one surface image, and a cost function for the matching process is developed using the distance image. The geometric transformation includes three- dimensional translation, rotation, and scaling to accommodate images of different position, orientation, and size. The matching process involves searching this multi-parameter space to find the best fit which minimizes the cost function. The local minima problem is addressed by using a large number of starting points. A pyramid multi-resolution approach is employed to speed up both the distance transformation and the multi-parameter minimization processes. Robustness in noise handling is accomplished using multiple thresholds embedded in the multi- resolution search. The algorithm can register both partially overlapped and fragmented surfaces. Manual intervention is generally not necessary. Preliminary results suggest registration accuracy on the order of the voxel size used in the registration process. Computational time scales with the number of matching elements used, with about five minutes typical for 2563 images using a modern desktop workstation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Maurer, C. R., Qi, R., & Raghavan, V. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1177156 · Cited by 911
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationMedical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Metadata
- Authors
- Jiang, H., Robb, R. A., & Holton Tainter, K. S.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1992-09-22
- Volume
- 1808
- Pages
- 196-213
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2090698554
- Cited by
- 162
- References
- 0
- FWCI
- 28.67
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New approach to 3-D registration of multimodality medical images by surface matching:. https://app.cochat.ai/papers/10.1117/12.131078
- The paper
- Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992). New approach to 3-D registration of multimodality medical images by surface matching:. SPIE Proceedings. https://doi.org/10.1117/12.131078
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.