CoChat

Light field image denoising using a linear 4D frequency-hyperfan all-in-focus filter

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Imaging in low light is problematic as sensor noise can dominate imagery, and increasing illumination or aperture size is not always effective or practical. Computational photography offers a promising solution in the form of the light field camera, which by capturing redundant information offers an opportunity for elegant noise rejection. We show that the light field of a Lambertian scene has a 4D hyperfan-shaped frequency-domain region of support at the intersection of a dual-fan and a hypercone. By designing and implementing a filter with appropriately shaped passband we accomplish denoising with a single all-in-focus linear filter. Drawing examples from the Stanford Light Field Archive and images captured using a commercially available lenselet- based plenoptic camera, we demonstrate that the hyperfan outperforms competing methods including synthetic focus, fan-shaped antialiasing filters, and a range of modern nonlinear image and video denoising techniques. We show the hyperfan preserves depth of field, making it a single-step all-in-focus denoising filter suitable for general-purpose light field rendering. We include results for different noise types and levels, over a variety of metrics, and in real-world scenarios. Finally, we show that the hyperfan’s performance scales with aperture count.

Overview

Integrity signals

Registry

Crossref · 10.1117/12.2002239

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 12 references

Cited by

See all 63

Metadata

Authors
Dansereau, D. G., Bongiorno, D. L., Pizarro, O., & Williams, S. B.
Affiliations
The University of Sydney (AU)
Venue
SPIE Proceedings
Publisher
SPIE
Published
2013-02-14
Volume
8657
Pages
86570P
ISSN
0277-786X (ISSN-L)
OpenAlex
W1986879390
Cited by
63
References
12
Citations by year
2025: 3 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 6 · 2020: 5 · 2019: 8 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 3 · 2014: 3 · 2013: 4
FWCI
3.62
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
Funders
  • Australian Government
  • New South Wales Government
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Enhancement Techniques
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Vision and Imaging
Keywords
plenoptic camera, low-light imaging, sensor noise, light field rendering, computational photography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Light field image denoising using a linear 4D frequency-hyperfan all-in-focus filter. https://app.cochat.ai/papers/10.1117/12.2002239
The paper
Dansereau, D. G., Bongiorno, D. L., Pizarro, O., & Williams, S. B. (2013). Light field image denoising using a linear 4D frequency-hyperfan all-in-focus filter. SPIE Proceedings. https://doi.org/10.1117/12.2002239

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.