CoChat

View-interpolation of sparsely sampled sinogram using convolutional neural network

Lee, Hoyeon, Lee, Jongha, Cho, Suengryong · 2017 · SPIE Proceedings

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Spare-view sampling and its associated iterative image reconstruction in computed tomography have actively investigated. Sparse-view CT technique is a viable option to low-dose CT, particularly in cone-beam CT (CBCT) applications, with advanced iterative image reconstructions with varying degrees of image artifacts. One of the artifacts that may occur in sparse-view CT is the streak artifact in the reconstructed images. Another approach has been investigated for sparse-view CT imaging by use of the interpolation methods to fill in the missing view data and that reconstructs the image by an analytic reconstruction algorithm. In this study, we developed an interpolation method using convolutional neural network (CNN), which is one of the widely used deep-learning methods, to find missing projection data and compared its performances with the other interpolation techniques.

Overview

Integrity signals

Registry

Crossref · 10.1117/12.2254244

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 15 references

Cited by

Metadata

Authors
Lee, H., Lee, J., & Cho, S.
Affiliations
  • Korea Institute of Science and Technology (KR)
  • Samsung Electronics (South Korea) (KR)
Venue
SPIE Proceedings
Publisher
SPIE
Published
2017-02-24
Volume
10133
Pages
1013328
ISSN
0277-786X (ISSN-L)
OpenAlex
W2593226005
Cited by
74
References
15
Citations by year
2026: 1 · 2025: 9 · 2024: 10 · 2023: 9 · 2022: 12 · 2021: 8 · 2020: 5 · 2019: 13 · 2018: 6 · 2017: 1
FWCI
13.67
Type
conference paper
Language
en
Open access
closed
Locations
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
  • The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
Keywords
sparse-view CT, sinogram interpolation, view interpolation, convolutional neural networks, streak artifacts, low-dose CT, cone-beam computed tomography, iterative reconstruction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.