Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 344

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study

Singh, Sarabjeet, Kalra, Mannudeep K., Gilman, Matthew D., Hsieh, Jiang, Pien, Homer H., Digumarthy, Subba R., Shepard, Jo-Anne O.·2011·Radiology

Abstract

PURPOSE: To compare lesion detection and image quality of chest computed tomographic (CT) images acquired at various tube current-time products (40-150 mAs) and reconstructed with adaptive statistical iterative reconstruction (ASIR) or filtered back projection (FBP). MATERIALS AND METHODS: In this Institutional Review Board-approved HIPAA-compliant study, CT data from 23 patients (mean age, 63 years ± 7.3 [standard deviation]; 10 men, 13 women) were acquired at varying tube current-time products (40, 75, 110, and 150 mAs) on a 64-row multidetector CT scanner with 10-cm scan length. All patients gave informed consent. Data sets were reconstructed at 30%, 50%, and 70% ASIR-FBP blending. Two thoracic radiologists assessed image noise, visibility of small structures, lesion conspicuity, and diagnostic confidence. Objective noise and CT number were measured in the thoracic aorta. CT dose index volume, dose-length product, weight, and transverse diameter were recorded. Data were analyzed by using analysis of variance and the Wilcoxon signed rank test. RESULTS: FBP had unacceptable noise at 40 and 75 mAs in 17 and five patients, respectively, whereas ASIR had acceptable noise at 40-150 mAs. Objective noise with 30%, 50%, and 70% ASIR blending (11.8 ± 3.8, 9.6 ± 3.1, and 7.5 ± 2.6, respectively) was lower than that with FBP (15.8 ± 4.8) (P < .0001). No lesions were missed on FBP or ASIR images. Lesion conspicuity was graded as well seen on both FBP and ASIR images (P < .05). Mild pixilated blotchy texture was noticed with 70% blended ASIR images. CONCLUSION: Acceptable image quality can be obtained for chest CT images acquired at 40 mAs by using ASIR without any substantial artifacts affecting diagnostic confidence. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101450/-/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11101450

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 344

Metadata

Authors
Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O.
Venue
Radiology
Published
2011-05
Volume
259
Issue
2
Pages
565-573
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2143129785
Cited by
344
References
20
FWCI
31.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study. https://app.cochat.ai/papers/10.1148/radiol.11101450
The paper
Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O. (2011). Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study. Radiology. https://doi.org/10.1148/radiol.11101450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.