The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study
Abstract
PURPOSE: To compare lesion detection and image quality of chest computed tomographic (CT) images acquired at various tube current-time products (40-150 mAs) and reconstructed with adaptive statistical iterative reconstruction (ASIR) or filtered back projection (FBP). MATERIALS AND METHODS: In this Institutional Review Board-approved HIPAA-compliant study, CT data from 23 patients (mean age, 63 years ± 7.3 [standard deviation]; 10 men, 13 women) were acquired at varying tube current-time products (40, 75, 110, and 150 mAs) on a 64-row multidetector CT scanner with 10-cm scan length. All patients gave informed consent. Data sets were reconstructed at 30%, 50%, and 70% ASIR-FBP blending. Two thoracic radiologists assessed image noise, visibility of small structures, lesion conspicuity, and diagnostic confidence. Objective noise and CT number were measured in the thoracic aorta. CT dose index volume, dose-length product, weight, and transverse diameter were recorded. Data were analyzed by using analysis of variance and the Wilcoxon signed rank test. RESULTS: FBP had unacceptable noise at 40 and 75 mAs in 17 and five patients, respectively, whereas ASIR had acceptable noise at 40-150 mAs. Objective noise with 30%, 50%, and 70% ASIR blending (11.8 ± 3.8, 9.6 ± 3.1, and 7.5 ± 2.6, respectively) was lower than that with FBP (15.8 ± 4.8) (P < .0001). No lesions were missed on FBP or ASIR images. Lesion conspicuity was graded as well seen on both FBP and ASIR images (P < .05). Mild pixilated blotchy texture was noticed with 70% blended ASIR images. CONCLUSION: Acceptable image quality can be obtained for chest CT images acquired at 40 mAs by using ASIR without any substantial artifacts affecting diagnostic confidence. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101450/-/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Self-citationA three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Self-citationIterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study
Hara, A. K., Paden, R. G., Silva, A. C., Kujak, J. L., Lawder, H. J., & Pavlicek, W. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2397 · Cited by 732
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533
Schauer, D. A., & Linton, O. W. (2009) · Health Physics · doi:10.1097/01.hp.0000356672.44380.b7 · Cited by 391
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Heyer, C. M., Mohr, P. S., Lemburg, S. P., Peters, S. A., & Nicolas, V. (2007) · Radiology · doi:10.1148/radiol.2452061919 · Cited by 274
Prakash, P., Kalra, M. K., Digumarthy, S. R., Hsieh, J., Pien, H., Singh, S., Gilman, M. D., & Shepard, J.-A. O. (2010) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3181b26c67 · Cited by 188
Self-citation
Cited by
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Katsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Metadata
- Authors
- Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O.
- Venue
- Radiology
- Published
- 2011-05
- Volume
- 259
- Issue
- 2
- Pages
- 565-573
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2143129785
- Cited by
- 344
- References
- 20
- FWCI
- 31.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study. https://app.cochat.ai/papers/10.1148/radiol.11101450
- The paper
- Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O. (2011). Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study. Radiology. https://doi.org/10.1148/radiol.11101450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.