CoChat

High-NA EUV lithography exposure tool: program progress

Van Schoot, Jan, van Setten, Eelco, Troost, Kars, Lok, Sjoerd, Stoeldraijer, Judon, Peeters, Rudy, Benschop, Jos, Zimmerman, Joerg, Graeupner, Paul, Wischmeier, Lars, Kuerz, Peter, Kaiser, Winfried · 2020 · Extreme Ultraviolet (EUV) Lithography XI
Cited by 60

The DOI matches its Crossref record.

Abstract

While EUV systems equipped with a 0.33 Numerical Aperture (NA) lens are entering high volume manufacturing, ASML and ZEISS are in parallel ramping up their activities on an EUV exposure tool with an NA of 0.55. The intent of this high-NA scanner, targeting a resolution of 8nm, is to extend Moore’s law throughout the next decade. The high-NA optical system, together with the developments in mask and resist, provides an increased contrast, key to control stochastic contributions to EPE and error rate of printing defects. A novel lens design, capable of providing the required NA, has been identified; this lens will be paired with new, faster stages and more accurate sensors enabling the tight focus and overlay control needed for future process nodes. Impact on system architecture and proposed solutions are described in this paper. In addition, we give a status update on the developments at ZEISS and ASML.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.2551491

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Van Schoot, J., van Setten, E., Troost, K., Lok, S., Stoeldraijer, J., Peeters, R., Benschop, J., Zimmerman, J., Graeupner, P., Wischmeier, L., Kuerz, P., & Kaiser, W.
Venue
Extreme Ultraviolet (EUV) Lithography XI
Publisher
SPIE
Published
2020-03-23
Pages
3
OpenAlex
W3014014393
Cited by
60
References
0
FWCI
13.07
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.