CoChat

Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopy

Open access
De Blasi, Roberto A. · 1997 · Journal of Biomedical Optics
Cited by 50

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Near infrared spectroscopy (NIRS) was used to measure oxygen consumption (V ˙ O2) in the human forearm with two different methods.V ˙ O2 was measured in ten patients, first by inducing a forearm venous occlusion and then an ischemia. The mean value ofV ˙ O2 was 3.3 6 1.1 mMO2 3 100 g−13min−1 during venous occlusion and 2.960.9 mMO2 3 100 g−13min−1 during ischemia. The difference between the two means was 0.4 mMO2 3 100 g−13min−1. A good agreement between the two methods was demonstrated. The results showed that NIRS is a useful tool for the measurement of V ˙ O2 . The venous occlusion method was the method of choice because it could be easily repeated at the bedside without causing any discomfort to the patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.269893

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
De Blasi, R. A.
Venue
Journal of Biomedical Optics
Published
1997
Volume
2
Issue
2
Pages
171
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2078340693
Cited by
50
References
5
FWCI
1.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.