Accurate NIRS measurement of muscle oxygenation by correcting the influence of a subcutaneous fat layer:
The DOI matches its Crossref record.
Abstract
Although the inhomogeneity of tissue structure affects the sensitivity of tissue oxygenation measurement by reflectance near-infrared spectroscopy, few analyses of this effect have been reported. In this study, the influence of a subcutaneous fat layer on muscle oxygenation measurement was investigated by Monte Carlo simulation and experimental studies. In the experiments, measurement sensitivity was examined by measuring the falling rate of oxygenation in occlusion tests on the forearm using a tissue oxygen monitor. The fat layer thickness was measured by ultrasonography. Results of the simulation and occlusion tests clearly showed that the presence of a fat layer greatly decreases the measurement sensitivity and increases the light intensity at the detector. The correction factors of sensitivity were obtained from this relationship and were successfully validated by experiments on 12 subjects whose fat layer thickness ranged from 3.5 to 8 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationNear-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“These findings have been supported by other researchers (Homma et al., 1996; Matsushita et al., 1998; Yamamoto et al., 1996; 1998) who have demonstrated reduced tissue absorbency with increasing levels of adipose tissue thickness.”
ResultHiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0644-y · Cited by 69
Metadata
- Authors
- Yamamoto, K., Niwayama, M., Lin, L., Shiga, T., Kudo, N., & Takahashi, M.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1998-01-01
- Volume
- 3194
- Pages
- 166-173
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2516320910
- Cited by
- 27
- References
- 0
- FWCI
- 14.28
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate NIRS measurement of muscle oxygenation by correcting the influence of a subcutaneous fat layer:. https://app.cochat.ai/papers/10.1117/12.301049
- The paper
- Yamamoto, K., Niwayama, M., Lin, L., Shiga, T., Kudo, N., & Takahashi, M. (1998). Accurate NIRS measurement of muscle oxygenation by correcting the influence of a subcutaneous fat layer:. SPIE Proceedings. https://doi.org/10.1117/12.301049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.