CoChat

Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans

Hiroyuki, Higuchi, Hamaoka, Takafumi, Sako, Takayuki, Nishio, Shinya, Kime, Ryotaro, Murakami, Motohide, Katsumura, Toshihito · 2002 · European Journal of Applied Physiology

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

The purposes of this study were to compare the deoxygenation patterns of the vastus lateralis (VL) and the lateral head of gastrocnemius (GL) and examine the relationship between the muscle oxygenation level and pulmonary oxygen uptake (VO(2)) during graded treadmill exercise. Changes in oxygenation in each muscle were measured using near infrared spectroscopy (NIRS). Eight healthy male subjects participated in this study. Two NIRS probes were placed on VL and GL, and thereafter the leg arteries were occluded in all subjects to enable normalization of the NIR signals. The subjects then walked at 4 km x h(-1) and 6 km x h(-1), and then ran continuously at speeds ranging from 8 km x h(-1) to 16 km x h(-1). The muscle oxygenation level was defined as being 100% at rest and 0% at its lowest value during occlusion. Pulmonary VO(2) was measured using indirect calorimetry. After the subjects had started walking, the muscle oxygenation in VL increased and exceeded the level at rest. Thereafter, the muscle oxygenation in both muscles decreased in relation to the increase in speed (P < 0.001). A significant difference in the level of muscle oxygenation between VL and GL was found at speeds of 10 km x h(-1) and 12 km x h(-1) (P < 0.05). The muscle oxygenation level at 16 km x h(-1) was [mean (SEM)] 51.9 (4.6)% in VL and 52.8 (3.6)% in GL. There was a negative relationship between pulmonary VO(2) and the muscle oxygenation level (VL: r=-0.803 to -0.986; GL: r=-0.848 to -0.963, P < 0.05).…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00421-002-0644-y

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Cited by

See all 73

Metadata

Authors
Hiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T.
Affiliations
  • Fukuoka University (JP)
  • Tokyo Medical University (JP)
Venue
European Journal of Applied Physiology
Published
2002-01-01
Volume
87
Issue
4-5
Pages
343-349
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W2093744337
Cited by
69
References
23
Citations by year
2026: 3 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 5 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 6 · 2013: 5 · 2012: 7
FWCI
6.08
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
muscle oxygenation, vastus lateralis, lateral gastrocnemius, muscle deoxygenation, treadmill walking, treadmill running, pulmonary oxygen uptake, exercise speed, near-infrared spectroscopy
MeSH terms
Adult, Ankle, Hemoglobins, Humans, Leg, Male, Oxygen Consumption, Respiratory Physiological Phenomena, Running, Walking, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans. https://app.cochat.ai/papers/10.1007/s00421-002-0644-y
The paper
Hiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002). Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-002-0644-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.