Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The purposes of this study were to compare the deoxygenation patterns of the vastus lateralis (VL) and the lateral head of gastrocnemius (GL) and examine the relationship between the muscle oxygenation level and pulmonary oxygen uptake (VO(2)) during graded treadmill exercise. Changes in oxygenation in each muscle were measured using near infrared spectroscopy (NIRS). Eight healthy male subjects participated in this study. Two NIRS probes were placed on VL and GL, and thereafter the leg arteries were occluded in all subjects to enable normalization of the NIR signals. The subjects then walked at 4 km x h(-1) and 6 km x h(-1), and then ran continuously at speeds ranging from 8 km x h(-1) to 16 km x h(-1). The muscle oxygenation level was defined as being 100% at rest and 0% at its lowest value during occlusion. Pulmonary VO(2) was measured using indirect calorimetry. After the subjects had started walking, the muscle oxygenation in VL increased and exceeded the level at rest. Thereafter, the muscle oxygenation in both muscles decreased in relation to the increase in speed (P < 0.001). A significant difference in the level of muscle oxygenation between VL and GL was found at speeds of 10 km x h(-1) and 12 km x h(-1) (P < 0.05). The muscle oxygenation level at 16 km x h(-1) was [mean (SEM)] 51.9 (4.6)% in VL and 52.8 (3.6)% in GL. There was a negative relationship between pulmonary VO(2) and the muscle oxygenation level (VL: r=-0.803 to -0.986; GL: r=-0.848 to -0.963, P < 0.05).…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Generally, these studies show an increase in muscle oxygenation from rest to walking and a decrease with increasing running speed.”
From A Comparison of Leg Muscle Oxygenation, Cardiorespiratory Responses, and Blood Lactate between Walking and Running at the Same Speed (2024) · cites this paper as [5]
In the citing paper
“between walking and running at a comfortable speed for both gait modes, which, according to the aforementioned [5,6] and other studies (e.g., Ref. [10]), is around 7 km/h.”
From A Comparison of Leg Muscle Oxygenation, Cardiorespiratory Responses, and Blood Lactate between Walking and Running at the Same Speed (2024) · cites this paper as [5]
In the citing paper
“Our findings regarding SmO2 (Figure 3) agree with those of Hiroyuki et al. [5]”
From A Comparison of Leg Muscle Oxygenation, Cardiorespiratory Responses, and Blood Lactate between Walking and Running at the Same Speed (2024) · cites this paper as [5]
In the citing paper
“For this reason, numerous studies have demonstrated a correlation between VO2 and changes in muscle oxygenation (Hiroyuki et al., 2002; Okushima et al., 2016; Wang et al., 2012).”
From Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running (2022) · cites this paper as Hiroyuki et al., 2002
In the citing paper
“Nonetheless, achieved SmO2min and perhaps in combination with a positive or negative deflection point, could infer cardiorespiratory fitness as pointed out in the data that SmO2min and VO2peak have a strong correlation (Hiroyuki et al., 2002; Wang et al., 2012).”
From Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running (2022) · cites this paper as Hiroyuki et al., 2002
Citations
Cites
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087 · cited 2×
“The NIR radiation penetrates half the distance between the radiation source and the detector from the skin surface (Patterson et al. 1989).”
BackgroundInfluentialRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 9×
“Quaresima et al. (1996) measured muscle oxygenation in VL using NIRS in subjects who ran at speeds up to 11 kmÆh–1.”
BackgroundMethodInfluentialSelf-citationTime-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329 · cited 2×
“The NIR time-resolved spectroscopy and NIR frequency-domain spectroscopy have been developed to quantify the path length and the absolute value of HbO2, Hbtot and SO2 in tissue (Chance et al. 1988; Hamaoka et al. 2000; Quaresima et al. 1998).”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationSkeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans
Sadamoto, T., Bonde-Petersen, F., & Suzuki, Y. (1983) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00429076 · Cited by 322 · cited 1×
“Intramuscular pressure has been measured during static exercise and has been shown to increase as a function of exercise intensity (Crenshaw et al. 1997; Sjøgaard et al. 1986; Sadamoto et al. 1983).”
BackgroundComparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.276.6.r1682 · Cited by 175 · cited 1×
“The findings suggest that NIRcws signals mostly reflect the haemoglobin in the blood, although there is a contradictory report (Tran et al. 1999).”
BackgroundGas exchange and peripheral diffusion limitation
WAGNER, P. D. (1992) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199201000-00010 · Cited by 127 · cited 2×
“The _ VO2 in the leg has been evaluated by measuring the blood flow and the arterio-venous difference in oxygen content (Wagner 1992; Knight et al. 1996; Hogan et al. 1991).”
MethodHomma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123 · cited 4×
“The NIRcws measurement value is influenced by the thickness of the fat layer ( Homma et al. 1996; Yamamoto et al. 1997; McCully and Hamaoka 2000).”
BackgroundInfluentialChristmass, M. A., DAWSON, B. T., Passeretto, P., & Arthur, P. G. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050614 · Cited by 120 · cited 5×
“When their levels of muscle oxygenation were recalculated using our calibration (100% at rest and 0% at the lowest level during arterial occlusion), the level of muscle oxygenation in the study of Christmass et al. (1999) was found to be approximately 70%.”
MethodInfluentialThe effect of overlying tissue on the spatial sensitivity profile of near-infrared spectroscopy
Okada, E., Firbank, M., & Delpy, D. T. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/007 · Cited by 102 · cited 2×
“The depth of penetration of the radiation was 1.5–2 cm (Patterson et al. 1989; Okada et al. 1995 ).”
BackgroundInfluential
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationDavis, S. L., Fadel, P. J., Cui, J., Thomas, G. D., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2005 · Cited by 179
“However, NIR spectroscopic studies are increasingly being conducted in subjects performing prolonged, dynamic exercise of large muscle masses (5, 10, 13, 18, 19, 26).”
BackgroundMuscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“(d) There are significant differences in the degree of deoxygenation between the vastus lateralis and gastrocnemius during treadmill running (Hiroyuki et al., 2002).”
BackgroundResultRegulation of Cellular Gas Exchange, Oxygen Sensing, and Metabolic Control
Clanton, T. L., Hogan, M. C., & Gladden, L. B. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120030 · Cited by 80
Tew, G. A., Ruddock, A. D., & Saxton, J. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1596-2 · Cited by 101
“Given that NIRS is increasingly being used to assess SmO2 and muscle blood volume changes during prolonged, dynamic exercise ( Hiroyuki et al. 2002; Neary et al. 2002; Shibuya and Tanaka 2003; Kawaguchi et al. 2006; Kennedy et al. 2006), it is important to establish the impact of skin blood flow changes on these measu…”
Method
Metadata
- Authors
- Hiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T.
- Affiliations
- Fukuoka University (JP)
- Tokyo Medical University (JP)
- ORCID
- Hamaoka, Takafumi
- Venue
- European Journal of Applied Physiology
- Published
- 2002-01-01
- Volume
- 87
- Issue
- 4-5
- Pages
- 343-349
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2093744337
- Cited by
- 69
- References
- 23
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 5 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 6 · 2013: 5 · 2012: 7
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- muscle oxygenation, vastus lateralis, lateral gastrocnemius, muscle deoxygenation, treadmill walking, treadmill running, pulmonary oxygen uptake, exercise speed, near-infrared spectroscopy
- MeSH terms
- Adult, Ankle, Hemoglobins, Humans, Leg, Male, Oxygen Consumption, Respiratory Physiological Phenomena, Running, Walking, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans. https://app.cochat.ai/papers/10.1007/s00421-002-0644-y
- The paper
- Hiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002). Oxygenation in vastus lateralis and lateral head of gastrocnemius during treadmill walking and running in humans. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-002-0644-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.