Quantitative muscle oxygenation measurement using NIRS with correction for the influence of a fat layer: comparison of oxygen consumption rates with measurements by other techniques:
The DOI matches its Crossref record.
Abstract
The inhomogeneity of tissue structure greatly affects the sensitivity of tissue oxygenation measurement by near-IR spectroscopy (NIRS). We have proposed a method for correcting the influence of a subcutaneous fat layer on muscle oxygenation measurements. In this study, we validated our correction method by measuring oxygen consumption rates of the forearm muscle and comparing the measurements with those obtained by other techniques. 31P-magnetic resonance spectroscopy and positron emission tomography (PET). In NIRS, Vo2mus was obtained from the falling rate of oxygenation in ischaemia tests. The values of Vo2mos were corrected using a curve of measurement sensitivity against fat layer thicknesses, which were measured by ultrasonography. The corrected Vo2mus showed greater values and less variation between individuals than did the uncorrected one. In the 31P-NMR measurements on 10 subjects, Vo2mus was estimated from changes in phosphocreatine. The corrected Vo2mus in NIRS correlated well with the measurements by 31P-NMR compared to the uncorrected Vo2mus. This result suggested that our correction method is valid. Vo2mus was also measured using PET in one of the authors. The measured values by NIRS. 31P-NMR and PET were 0.22, 0.17, 0.24 ml 100g-1 min-1, respectively. The measurement by NIRS using our correction method was in an acceptable range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
“detector separation being 15 to 40 mm.(39,42,43) The curve was obtained from the results of both Monte Carlo simulation and in-vivo experiments.”
MethodSelf-citationHiroyuki, H., Hamaoka, T., Sako, T., Nishio, S., Kime, R., Murakami, M., & Katsumura, T. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0644-y · Cited by 69
“The NIRcws signal is reduced to one-fifth by a subcutaneous fat thickness of 1 cm, in comparison to that observed in the absence of subcutaneous fat (Niwayama et al. 2000).”
BackgroundSelf-citationde Ruiter, C. J., de Boer, M. D., Spanjaard, M., & de Haan, A. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01420.2004 · Cited by 69
Metadata
- Authors
- Niwayama, M., Hamaoka, T., Lin, L., Shao, J., Kudo, N., Katoh, C., & Yamamoto, K.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2000-05-03
- Volume
- 3911
- Pages
- 256-265
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2093220118
- Cited by
- 16
- References
- 0
- FWCI
- 6.67
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.