Compact fiber-pigtailed terahertz imaging system
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Terahertz imaging has been shown to be a powerful tool for analyzing a variety of materials. From the amount of water in a leaf over time to looking at the spectroscopic species in a flame, this technique shows great potential for commercial applications. However, in order to work in a commercial environment, the present free-space optical systems must be abandoned in favor of fiber-optic delivery. To this end, we have developed a compact, fiber-pigtailed terahertz imaging system that utilizes a hermetically sealed, photoconductive, transmitter and receiver. The receiver uses an integrated amplifier to obtain a 1000:1 S/N with only 1 mW of power on both the transmitter and receiver and with a one second integration time. This system has usable energy extending from 0.04 to 2 THz and has both a rapid (20 Hz) scanner for short, 40-ps, scans as well as a long rail for scans up to 1 ns. The system hardware is contained in a 1.5 cu. ft. box with fibers feeding both the transceiver units. These units can be configured into either a transmission or reflection mode depending on the user's application. An advanced software system controls the hardware, collects the data, and does image processing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Cited by
The 2017 terahertz science and technology roadmap
Dhillon, S. S., Vitiello, M. S., Linfield, E. H., Davies, A. G., Hoffmann, M. C., Booske, J., Paoloni, C., Gensch, M., Weightman, P., Williams, G. P., et al. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/50/4/043001 · Cited by 1,503
Metal wires for terahertz wave guiding
Wang, K., & Mittleman, D. M. (2004) · Nature · doi:10.1038/nature03040 · Cited by 1,075
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
Perspective: Terahertz science and technology
Mittleman, D. M. (2017) · Journal of Applied Physics · doi:10.1063/1.5007683 · Cited by 383
Metadata
- Authors
- Rudd, J. V., Zimdars, D. A., & Warmuth, M. W.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2000-05-23
- Volume
- 3934
- Pages
- 27
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1980459721
- Cited by
- 68
- References
- 1
- FWCI
- 17.29
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compact fiber-pigtailed terahertz imaging system. https://app.cochat.ai/papers/10.1117/12.386344
- The paper
- Rudd, J. V., Zimdars, D. A., & Warmuth, M. W. (2000). Compact fiber-pigtailed terahertz imaging system. SPIE Proceedings. https://doi.org/10.1117/12.386344
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.