CoChat

Experimental study of migration depth for the photons measured at sample surface:

Cui, Weijia, Kumar, Chellappa, Chance, Britton · 1991 · SPIE Proceedings
Cited by 142

The DOI matches its Crossref record.

Abstract

Optical imaging of in vivo tissue and noninvasive optical assessment of deep tissue requires knowledge concerning photon migration paths in the medium. We used intralipid emulsion as a phantom medium to study the distribution of the migration paths. An incident and receiving optical fibers were placed on the medium surface. Light at 760 nm was used. An absorber was placed in the medium at different locations to intersect different photon paths. The study shows that the incident photons migrate to the detector through the paths distributed in a region shaped a 'banana', with its two end connecting the source and detector and it mid portion reaching deepest. This region has a core connecting the source and detector through which the photons have maximum probability to take. The path distribution in depth across the mid portion of the 'banana' and through the core can be described by a random walk model, with its maximum probability at a certain depth below the surface. In this study, this maximum probability depth ranged from 3 millimeters to about 7 or 8 millimeters. The path distribution across the mid portion of the 'banana' horizontally and through the core can be described by a normal probability function. These distributions are affected by the optical properties of the medium and the source-detector separation. This study indicated the capability of using surface optical measurement to image the optical property distribution of in vivo tissue and to assess deep tissue optical properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.44189

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Cui, W., Kumar, C., & Chance, B.
Venue
SPIE Proceedings
Publisher
SPIE
Published
1991-05-01
Volume
1431
Pages
180-191
ISSN
0277-786X (ISSN-L)
OpenAlex
W1971042011
Cited by
142
References
0
FWCI
8.93
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental study of migration depth for the photons measured at sample surface:. https://app.cochat.ai/papers/10.1117/12.44189
The paper
Cui, W., Kumar, C., & Chance, B. (1991). Experimental study of migration depth for the photons measured at sample surface:. SPIE Proceedings. https://doi.org/10.1117/12.44189

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.