Experimental study of migration depth for the photons measured at sample surface:
The DOI matches its Crossref record.
Abstract
Optical imaging of in vivo tissue and noninvasive optical assessment of deep tissue requires knowledge concerning photon migration paths in the medium. We used intralipid emulsion as a phantom medium to study the distribution of the migration paths. An incident and receiving optical fibers were placed on the medium surface. Light at 760 nm was used. An absorber was placed in the medium at different locations to intersect different photon paths. The study shows that the incident photons migrate to the detector through the paths distributed in a region shaped a 'banana', with its two end connecting the source and detector and it mid portion reaching deepest. This region has a core connecting the source and detector through which the photons have maximum probability to take. The path distribution in depth across the mid portion of the 'banana' and through the core can be described by a random walk model, with its maximum probability at a certain depth below the surface. In this study, this maximum probability depth ranged from 3 millimeters to about 7 or 8 millimeters. The path distribution across the mid portion of the 'banana' horizontally and through the core can be described by a normal probability function. These distributions are affected by the optical properties of the medium and the source-detector separation. This study indicated the capability of using surface optical measurement to image the optical property distribution of in vivo tissue and to assess deep tissue optical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
The prognostic value of muscle StO2 in septic patients
Creteur, J., Carollo, T., Soldati, G., Buchele, G., De Backer, D., & Vincent, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0739-3 · Cited by 355
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
“Fortunately, there is the concept of ``mean photon path'' through tissue between light source and detector which establishes the most likely path a photon will take [4].”
Kohno, S., Miyai, I., Seiyama, A., Oda, I., Ishikawa, A., Tsuneishi, S., Amita, T., & Shimizu, K. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2814249 · Cited by 233
Kuebler, W. M., Sckell, A., Habler, O., Kleen, M., Kuhnle, G. E. H., Welte, M., Messmer, K., & Goetz, A. E. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199804000-00013 · Cited by 206
“II for transfor mation of BFI into CBF data to measurements in porcine head, Cui et al. (1991) have described the mean path of near-infrared photons through turbid biological media when both source and detector are in the same plane by a "banana shape" with ends connecting the source and detector…”
MethodMyers, D. E., Anderson, L. D., Seifert, R. P., Ortner, J. P., Cooper, C. E., Beilman, G. J., & Mowlem, J. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1925250 · Cited by 187
de Ruiter, C. J., de Boer, M. D., Spanjaard, M., & de Haan, A. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01420.2004 · Cited by 69
Messere, A., & Roatta, S. (2013) · Physiological Reports · doi:10.1002/phy2.179 · Cited by 63
“Increasing the distance between emitting and detecting optodes is known to increase the depth of penetration of infrared light (Cui et al. 1991; McCully and Hamaoka 2000); however, this expedient minimizes but does not”
Background
Metadata
- Authors
- Cui, W., Kumar, C., & Chance, B.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1991-05-01
- Volume
- 1431
- Pages
- 180-191
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1971042011
- Cited by
- 142
- References
- 0
- FWCI
- 8.93
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.