Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record.

SIRUS: a near infrared simultaneous three-band camera

Nagayama, Takahiro, Nagashima, Chie, Nakajima, Yasushi, Nagata, Tetsuya, Sato, Shuji, Nakaya, Hidehiko, Yamamuro, Tomoyasu, Sugitani, Koji, Tamura, Motohide·2003·SPIE Proceedings

Abstract

We developed a near infrared simultaneous three-band (J, H and Ks) camera, SIRIUS. The design of SIRIUS is optimized to deep, large area surveys in the three IR bands. SIRIUS is equipped with three 1024 x 1024 HgCdTe (HAWAII) arrays, providing simultaneous three-band images. SIRIUS has obtained its first light on the UH 2.2 m telescope in August 2000. SIRIUS is now mounted on the IRSF 1.4 m telescope in Sutherland and is dedicated to deep survey in the southern sky from November 2000. On this telescope, SIRIUS provides 7'.8 x 7'.8 field of view with a pixel scale of 0".45 in all bands. The typical limiting magnitudes are J = 19.2 mag, H = 18.6 mag, Ks = 17.3 mag (15 min. integration, S/N = 10 σ). The effective exposure time (30 sec exposure for each frame) in an hour is about 37 minutes (60%) for each band. Both the instrument and the 1.4 m telescope are in operation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.460770

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 261

Metadata

Authors
Nagayama, T., Nagashima, C., Nakajima, Y., Nagata, T., Sato, S., Nakaya, H., Yamamuro, T., Sugitani, K., & Tamura, M.
Venue
SPIE Proceedings
Publisher
SPIE
Published
2003-03-07
Volume
4841
Pages
459
ISSN
0277-786X (ISSN-L)
OpenAlex
W2020298240
Cited by
261
References
0
FWCI
12.95
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SIRUS: a near infrared simultaneous three-band camera. https://app.cochat.ai/papers/10.1117/12.460770
The paper
Nagayama, T., Nagashima, C., Nakajima, Y., Nagata, T., Sato, S., Nakaya, H., Yamamuro, T., Sugitani, K., & Tamura, M. (2003). SIRUS: a near infrared simultaneous three-band camera. SPIE Proceedings. https://doi.org/10.1117/12.460770

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.