The DOI matches its Crossref record.
Temperature-dependent absolute refractive index measurements of synthetic fused silica
Open accessAbstract
Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from temperatures ranging from 30 to 310 K at wavelengths from 0.4 to 2.6 microns with an absolute uncertainty of +/-1 x 10^-5. Statistical variations in derived values of the thermo-optic coefficient (dn/dT) are at the +/-2 x 10^-8/K level. Graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient are presented for selected wavelengths and temperatures along with estimates of uncertainty in index. Coefficients for temperature-dependent Sellmeier fits of measured refractive index are also presented to allow accurate interpolation of index to other wavelengths and temperatures. We compare our results to those from an independent investigation (which used an interferometric technique for measuring index changes as a function of temperature) whose samples were prepared from the same slugs of material from which our prisms were prepared in support of the Kepler mission. We also compare our results with sparse cryogenic index data from measurements of this material from the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arbabi, A., & Goddard, L. L. (2013) · Optics Letters · doi:10.1364/ol.38.003878 · Cited by 331
Polarization entangled photon-pair source based on quantum nonlinear photonics and interferometry
Kaiser, F., Ngah, L. A., Issautier, A., Delord, T., Aktas, D., D׳Auria, V., De Micheli, M. P., Kastberg, A., Labonté, L., Alibart, O., et al. (2014) · Optics Communications · doi:10.1016/j.optcom.2014.03.056 · Cited by 34
Optical absorption measurement at 1550 nm on a highly-reflective Si/SiO 2 coating stack
Steinlechner, J., Khalaidovski, A., & Schnabel, R. (2014) · Classical and Quantum Gravity · doi:10.1088/0264-9381/31/10/105005 · Cited by 14
Metadata
- Authors
- Leviton, D. B., & Frey, B. J.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2006-06-14
- Volume
- 6273
- Pages
- 62732K
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2079703146
- Cited by
- 226
- References
- 0
- FWCI
- 6.09
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature-dependent absolute refractive index measurements of synthetic fused silica. https://app.cochat.ai/papers/10.1117/12.672853
- The paper
- Leviton, D. B., & Frey, B. J. (2006). Temperature-dependent absolute refractive index measurements of synthetic fused silica. SPIE Proceedings. https://doi.org/10.1117/12.672853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.