The DOI matches its Crossref record.
Trends in synchrotron-based tomographic imaging: the SLS experience
Open accessAbstract
Synchrotron-based X-ray Tomographic Microscopy (SRXTM) is nowadays a powerful technique for non-destructive, high-resolution investigations of a broad kind of materials. High-brilliance and high-coherence third generation synchrotron radiation facilities allow micrometer and sub-micrometer, quantitative, three-dimensional imaging within very short time and extend the traditional absorption imaging technique to edge-enhanced and phase-sensitive measurements. At the Swiss Light Source TOMCAT, a new beamline for TOmographic Microscopy and Coherent rAdiology experimenTs, has been recently built and started regular user operation in June 2006. The new beamline get photons from a 2.9 T superbend with a critical energy of 11.1 keV. This makes energies above 20 keV easily accessible. To guarantee the best beam quality (stability and homogeneity), the number of optical elements has been kept to a minimum. A Double Crystal Multilayer Monochromator (DCMM) covers an energy range between 8 and 45 keV with a bandwidth of a few percent down to 10-4. The beamline can also be operated in white-beam mode, providing the ideal conditions for real-time coherent radiology. This article presents the beamline design, its optical components and the endstation. It further illustrates two recently developed phase contrast techniques and finally gives an overview of recent research topics which make intense use of SRXTM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visualization and Quantification of Electrochemical and Mechanical Degradation in Li Ion Batteries
Ebner, M., Marone, F., Stampanoni, M., & Wood, V. (2013) · Science · doi:10.1126/science.1241882 · Cited by 695
Self-citationRegridding reconstruction algorithm for real-time tomographic imaging
Marone, F., & Stampanoni, M. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512032864 · Cited by 441
Self-citationHuldtgren, T., Cunningham, J. A., Yin, C., Stampanoni, M., Marone, F., Donoghue, P. C. J., & Bengtson, S. (2011) · Science · doi:10.1126/science.1209537 · Cited by 171
Self-citationPhenotypic plasticity of coralline algae in a High CO2 world
Ragazzola, F., Foster, L. C., Form, A. U., Büscher, J., Hansteen, T. H., & Fietzke, J. (2013) · Ecology and Evolution · doi:10.1002/ece3.723 · Cited by 70
Advantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
Self-citation
Metadata
- Authors
- Stampanoni, M., Groso, A., Isenegger, A., Mikuljan, G., Chen, Q., Bertrand, A., Henein, S., Betemps, R., Frommherz, U., Böhler, P., Meister, D., Lange, M., & Abela, R.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2006-08-31
- Volume
- 6318
- Pages
- 63180M
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2067856121
- Cited by
- 304
- References
- 0
- FWCI
- 14.99
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trends in synchrotron-based tomographic imaging: the SLS experience. https://app.cochat.ai/papers/10.1117/12.679497
- The paper
- Stampanoni, M., Groso, A., Isenegger, A., Mikuljan, G., Chen, Q., Bertrand, A., Henein, S., Betemps, R., Frommherz, U., Böhler, P., Meister, D., Lange, M., & Abela, R. (2006). Trends in synchrotron-based tomographic imaging: the SLS experience. SPIE Proceedings. https://doi.org/10.1117/12.679497