Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

A Free Response Approach To The Measurement And Characterization Of Radiographic Observer Performance:

Bunch, Philip C., Hamilton, John F., Sanderson, Gary K., Simmons, Arthur H.·1977·SPIE Proceedings

Abstract

Radiographic signal detection is considered to be a point process. Realism of radio-graphic signal detection experiments is extended by allowing a random number of signals and by requiring accurate location of the signals. A substantial improvement in the simplicity of the theoretical framework of multiple signal detection experiments results from using this free response approach. The generation of false positive events is adequately described as a Poisson process, represented by a single measurable parameter. A scheme for reinterpretation of earlier conventional Receiver Operating Characteristic (ROC) curves in terms of the free response approach is presented, and a description of a much simpler and more efficient experimental procedure is provided.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.955926

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Bunch, P. C., Hamilton, J. F., Sanderson, G. K., & Simmons, A. H.
Venue
SPIE Proceedings
Publisher
SPIE
Published
1977-12-27
Volume
0127
Pages
124-135
ISSN
0277-786X (ISSN-L)
OpenAlex
W2073383890
Cited by
212
References
0
FWCI
0.00
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Free Response Approach To The Measurement And Characterization Of Radiographic Observer Performance:. https://app.cochat.ai/papers/10.1117/12.955926
The paper
Bunch, P. C., Hamilton, J. F., Sanderson, G. K., & Simmons, A. H. (1977). A Free Response Approach To The Measurement And Characterization Of Radiographic Observer Performance:. SPIE Proceedings. https://doi.org/10.1117/12.955926

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.