The DOI matches its Crossref record.
Prostate boundary segmentation from 2D ultrasound images
Abstract
Outlining, or segmenting, the prostate is a very important task in the assignment of appropriate therapy and dose for cancer treatment; however, manual outlining is tedious and time‐consuming. In this paper, an algorithm is described for semiautomatic segmentation of the prostate from 2D ultrasound images. The algorithm uses model‐based initialization and the efficient discrete dynamic contour. Initialization requires the user to select only four points from which the outline of the prostate is estimated using cubic interpolation functions and shape information. The estimated contour is then deformed automatically to better fit the image. The algorithm can easily segment a wide range of prostate images, and contour editing tools are included to handle more difficult cases. The performance of the algorithm with a single user was compared to manual outlining by a single expert observer. The average distance between semiautomatically and manually outlined boundaries was found to be less than 5 pixels (0.63 mm), and the accuracy and sensitivity to area measurements were both over 90%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Self-citationTissue elasticity properties as biomarkers for prostate cancer
Hoyt, K., Castaneda, B., Zhang, M., Nigwekar, P., di Sant'Agnese, P. A., Joseph, J. V., Strang, J., Rubens, D. J., & Parker, K. J. (2008) · Cancer Biomarkers · doi:10.3233/cbm-2008-44-505 · Cited by 303
Generalizable Multi-Site Training and Testing Of Deep Neural Networks Using Image Normalization
Onofrey, J. A., Casetti-Dinescu, D. I., Lauritzen, A. D., Sarkar, S., Venkataraman, R., Fan, R. E., Sonn, G. A., Sprenkle, P. C., Staib, L. H., & Papademetris, X. (2019) · 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019) · doi:10.1109/isbi.2019.8759295 · Cited by 52
Metadata
- Authors
- Ladak, H. M., Mao, F., Wang, Y., Downey, D. B., Steinman, D. A., & Fenster, A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2000-08
- Volume
- 27
- Issue
- 8
- Pages
- 1777-1788
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2016302913
- Cited by
- 177
- References
- 0
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prostate boundary segmentation from 2D ultrasound images. https://app.cochat.ai/papers/10.1118/1.1286722
- The paper
- Ladak, H. M., Mao, F., Wang, Y., Downey, D. B., Steinman, D. A., & Fenster, A. (2000). Prostate boundary segmentation from 2D ultrasound images. Medical Physics. https://doi.org/10.1118/1.1286722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.