The DOI matches its Crossref record.
Automated detection of lung nodules in CT scans: Preliminary results
Abstract
We have developed a fully automated computerized method for the detection of lung nodules in helical computed tomography (CT) scans of the thorax. This method is based on two‐dimensional and three‐dimensional analyses of the image data acquired during diagnostic CT scans. Lung segmentation proceeds on a section‐by‐section basis to construct a segmented lung volume within which further analysis is performed. Multiple gray‐level thresholds are applied to the segmented lung volume to create a series of thresholded lung volumes. An 18‐point connectivity scheme is used to identify contiguous three‐dimensional structures within each thresholded lung volume, and those structures that satisfy a volume criterion are selected as initial lung nodule candidates. Morphological and gray‐level features are computed for each nodule candidate. After a rule‐based approach is applied to greatly reduce the number of nodule candidates that corresponds to non‐nodules, the features of remaining candidates are merged through linear discriminant analysis. The automated method was applied to a database of 43 diagnostic thoracic CT scans. Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate nodule candidates that correspond to actual nodules from false‐positive candidates. The area under the ROC curve for this categorization task attained a value of 0.90 during leave‐one‐out‐by‐case evaluation. The automated method yielded an overall nodule detection sensitivity of 70% with an average of 1.5 false‐positive detections per section when applied to the complete 43‐case database. A corresponding nodule detection sensitivity of 89% with an average of 1.3 false‐positive detections per section was achieved with a subset of 20 cases that contained only one or two nodules per case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
A new computationally efficient CAD system for pulmonary nodule detection in CT imagery
Messay, T., Hardie, R. C., & Rogers, S. K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.02.004 · Cited by 439
Quantifying tumour heterogeneity with CT
Ganeshan, B., & Miles, K. A. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0015 · Cited by 395
Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Self-citationGaneshan, B., Abaleke, S., Young, R. C. D., Chatwin, C. R., & Miles, K. A. (2010) · Cancer Imaging · doi:10.1102/1470-7330.2010.0021 · Cited by 324
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationGurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
van Ginneken, B., Armato, S. G., de Hoop, B., van Amelsvoort-van de Vorst, S., Duindam, T., Niemeijer, M., Murphy, K., Schilham, A., Retico, A., Fantacci, M. E., et al. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.005 · Cited by 298
Self-citationShape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 280
Self-citationComputer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Self-citationAutomated lung segmentation for thoracic CT
Armato, S. G., & Sensakovic, W. F. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.06.005 · Cited by 259
Self-citationRubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Rios Velazquez, E., Aerts, H. J. W. L., Gu, Y., Goldgof, D. B., De Ruysscher, D., Dekker, A., Korn, R., Gillies, R. J., & Lambin, P. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.09.023 · Cited by 120
“In this regard, automatic methods to interpret chest CT images have largely focused on the early detection of lung nodules [34,35], on the differential diagnosis of malignant versus benign nodules [36] and in the measurement of nodule or tumor size as treatment response criteria [37,38].”
Method
Metadata
- Authors
- Armato, S. G., Giger, M. L., & MacMahon, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 28
- Issue
- 8
- Pages
- 1552-1561
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2083432437
- Cited by
- 250
- References
- 0
- FWCI
- 15.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.