The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
Abstract
Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantification. Motion artifacts lead to two major effects: First, it affects the accuracy of quantitation, producing a reduction of the measured standard uptake value (SUV). Second, the apparent lesion volume is overestimated. Both impact upon the usage of PET images for radiation treatment planning. The first affects the visibility, or contrast, of the lesion. The second results in an increase in the planning target volume, and consequently a greater radiation dose to the normal tissues. One way to compensate for this effect is by applying a multiple‐frame capture technique. The PET data are then acquired in synchronization with the respiratory motion. Reduction in smearing due to gating was investigated in both phantoms and patient studies. Phantom studies showed a dependence of the reduction in smearing on the lesion size, the motion amplitude, and the number of bins used for data acquisition. These studies also showed an improvement in the target‐to‐background ratio, and a more accurate measurement of the SUV. When applied to one patient, respiratory gating showed a 28% reduction in the total lesion volume, and a 56.5% increase in the SUV. This study was conducted as a proof of principle that a gating technique can effectively reduce motion artifacts in PET image acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUV: standard uptake or silly useless value?
Keyes, J. W. (1995) · PubMed · Cited by 803
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
Larson, S. (1999) · Clinical Positron Imaging · doi:10.1016/s1095-0397(99)00016-3 · Cited by 598
Self-citationStrauss, L. G. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01367602 · Cited by 527
Performance characteristics of a whole-body PET scanner.
DeGrado, T. R., Turkington, T. G., Williams, J. J., Stearns, C. W., Hoffman, J. M., & Coleman, R. E. (1994) · PubMed · Cited by 515
Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
Erdi, Y. E., Mawlawi, O., Larson, S. M., Imbriaco, M., Yeung, H., Finn, R., & Humm, J. L. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971215)80:12+<2505::aid-cncr24>3.0.co;2-f · Cited by 480
Self-citationRespiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457
Wahl, R. L., Quint, L. E., Greenough, R. L., Meyer, C. R., White, R. I., & Orringer, M. B. (1994) · Radiology · doi:10.1148/radiology.191.2.8153308 · Cited by 430
Steinert, H. C., Hauser, M., Allemann, F., Engel, H., Berthold, T., von Schulthess, G. K., & Weder, W. (1997) · Radiology · doi:10.1148/radiology.202.2.9015071 · Cited by 376
Detecting recurrent or residual lung cancer with FDG-PET
(1995) · Lung Cancer · doi:10.1016/0169-5002(95)90602-9 · Cited by 203
Persistent or recurrent bronchogenic carcinoma: detection with PET and 2-[F-18]-2-deoxy-D-glucose.
Patz, E. F., Lowe, V. J., Hoffman, J. M., Paine, S., Harris, L. K., & Goodman, P. C. (1994) · Radiology · doi:10.1148/radiology.191.2.8153309 · Cited by 202
Use of PET to monitor the response of lung cancer to radiation treatment
Erdi, Y., Macapinlac, H., Rosenzweig, K., Humm, J., Larson, S., Erdi, A. K., & Yorke, E. (2000) · European Journal of Nuclear Medicine · doi:10.1007/s002590000258 · Cited by 141
Self-citationRamos, C. D., Erdi, Y. E., Gönen, M., Riedel, E., YEUNG, H. W. D., Macapinlac, H. A., Chisin, R., & Larson, S. M. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000421 · Cited by 139
Self-citation
Cited by
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Self-citationStereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
4-dimensional computed tomography imaging and treatment planning
KEALL, P. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.006 · Cited by 484
Four‐dimensional (4D) PET/CT imaging of the thorax
Nehmeh, S. A., Erdi, Y. E., Pan, T., Pevsner, A., Rosenzweig, K. E., Yorke, E., Mageras, G. S., Schoder, H., Vernon, P., Squire, O., et al. (2004) · Medical Physics · doi:10.1118/1.1809778 · Cited by 349
Self-citation
Metadata
- Authors
- Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Squire, O. D., Braban, L. E., Ford, E., Sidhu, K., Mageras, G. S., Larson, S. M., & Humm, J. L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2002-02-21
- Volume
- 29
- Issue
- 3
- Pages
- 366-371
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2152683426
- Cited by
- 297
- References
- 13
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.