4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Abstract
We propose a new scanning protocol for generating 4D-CT image data sets influenced by respiratory motion. A cine scanning protocol is used during data acquisition, and two registration methods are used to sort images into temporal phases. A volume is imaged in multiple acquisitions of 1 or 2 cm length along the cranial-caudal direction. In each acquisition, the scans are continuously acquired for a time interval greater than or equal to the average respiratory cycle plus the duration of the data for an image reconstruction. The x ray is turned off during CT table translation and the acquisition is repeated until the prescribed volume is completely scanned. The scanning for 20 cm coverage takes about 1 min with an eight-slice CT or 2 mins with a four-slice CT. After data acquisition, the CT data are registered into respiratory phases based on either an internal anatomical match or an external respiratory signal. The internal approach registers the data according to correlation of anatomy in the CT images between two adjacent locations in consecutive respiratory cycles. We have demonstrated the technique with ROIs placed in the region of diaphragm. The external approach registers the image data according to an externally recorded respiratory signal generated by the Real-Time Position Management (RPM) Respiratory Gating System (Varian Medical Systems, Palo Alto, CA). Compared with previously reported prospective or retrospective imaging of the respiratory motion with a single-slice or multi-slice CT, the 4D-CT method proposed here provides (1) a shorter scan time of three to six times faster than the single-slice CT with prospective gating; (2) a shorter scan time of two to four times improvement over a previously reported multi-slice CT implementation, and (3) images over all phases of a breathing cycle. We have applied the scanning and registration methods on phantom, animal and patients, and initial results suggest the applicability of both the scanning and the registration methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal short scan convolution reconstruction for fan beam CT
Parker, D. L. (1982) · Medical Physics · doi:10.1118/1.595078 · Cited by 525
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Low, D. A., Nystrom, M., Kalinin, E., Parikh, P., Dempsey, J. F., Bradley, J. D., Mutic, S., Wahab, S. H., Islam, T., Christensen, G., et al. (2003) · Medical Physics · doi:10.1118/1.1576230 · Cited by 475
Effect of respiratory gating on quantifying PET images of lung cancer.
Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Schöder, H. M., Larson, S. M., Macapinlac, H. A., Squire, O. D., & Humm, J. L. (2002) · PubMed · Cited by 406
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Squire, O. D., Braban, L. E., Ford, E., Sidhu, K., Mageras, G. S., Larson, S. M., et al. (2002) · Medical Physics · doi:10.1118/1.1448824 · Cited by 297
Kachelriess, M., & Kalender, W. A. (1998) · Medical Physics · doi:10.1118/1.598453 · Cited by 212
Potential radiotherapy improvements with respiratory gating
Keall, P. J., Kini, V. R., Vedam, S. S., & Mohan, R. (2002) · Australasian Physics & Engineering Sciences in Medicine · doi:10.1007/bf03178368 · Cited by 162
Cited by
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 317
Understanding Sources of Variation to Improve the Reproducibility of Radiomics
Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633176 · Cited by 158
Enhancing Cardiac PET by Motion Correction Techniques
Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J. (2017) · Current Cardiology Reports · doi:10.1007/s11886-017-0825-2 · Cited by 48
Metadata
- Authors
- Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2004-01-26
- Volume
- 31
- Issue
- 2
- Pages
- 333-340
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2062462385
- Cited by
- 624
- References
- 7
- FWCI
- 57.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. https://app.cochat.ai/papers/10.1118/1.1639993
- The paper
- Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004). 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Medical Physics. https://doi.org/10.1118/1.1639993
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.