Computerized characterization of breast masses on three‐dimensional ultrasound volumes

Open access
Sahiner, Berkman, Chan, Heang‐Ping, Roubidoux, Marilyn A., Helvie, Mark A., Hadjiiski, Lubomir M., Ramachandran, Aditya, Paramagul, Chintana, LeCarpentier, Gerald L., Nees, Alexis, Blane, Caroline · 2004 · Medical Physics
Cited by 70

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We are developing computer vision techniques for the characterization of breast masses as malignant or benign on radiologic examinations. In this study, we investigated the computerized characterization of breast masses on three‐dimensional (3‐D) ultrasound (US) volumetric images. We developed 2‐D and 3‐D active contour models for automated segmentation of the mass volumes. The effect of the initialization method of the active contour on the robustness of the iterative segmentation method was studied by varying the contour used for its initialization. For a given segmentation, texture and morphological features were automatically extracted from the segmented masses and their margins. Stepwise discriminant analysis with the leave‐one‐out method was used to select effective features for the classification task and to combine these features into a malignancy score. The classification accuracy was evaluated using the area under the receiver operating characteristic (ROC) curve, as well as the partial area index defined as the relative area under the ROC curve above a sensitivity threshold of 0.9. For the purpose of comparison with the computer classifier, four experienced breast radiologists provided malignancy ratings for the 3‐D US masses. Our dataset consisted of 3‐D US volumes of 102 biopsied masses (46 benign, 56 malignant). The classifiers based on 2‐D and 3‐D segmentation methods achieved test values of 0.87±0.03 and 0.92±0.03, respectively. The difference in the values of the two computer classifiers did not achieve statistical significance. The values of the four radiologists ranged between 0.84 and 0.92. The difference between the computer's value and that of any of the four radiologists did not achieve statistical significance either. However, the computer's value was significantly higher than that of three of the four radiologists. Our results indicate that an automated and effective computer classifier can be designed for differentiating malignant and benign breast masses on 3‐D US volumes. The accuracy of the classifier designed in this study was similar to that of experienced breast radiologists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.1649531

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Sahiner, B., Chan, H., Roubidoux, M. A., Helvie, M. A., Hadjiiski, L. M., Ramachandran, A., Paramagul, C., LeCarpentier, G. L., Nees, A., & Blane, C.
Venue
Medical Physics
Publisher
Wiley
Published
2004-03-11
Volume
31
Issue
4
Pages
744-754
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2094872149
Cited by
70
References
1
FWCI
7.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.