The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Four‐dimensional (4D) PET/CT imaging of the thorax
Abstract
We have reported in our previous studies on the methodology, and feasibility of 4D‐PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four lung cancer patients were monitored by tracking external markers placed on the thorax. A 4D‐CT acquisition was performed using a “step‐and‐shoot” technique, in which computed tomography (CT) projection data were acquired over a complete respiratory cycle at each couch position. The period of each CT acquisition segment was time stamped with an “x‐ray ON” signal, which was recorded by the tracking system. 4D‐CT data were then sorted into 10 groups, according to their corresponding phase of the breathing cycle. 4D‐PET data were acquired in the gated mode, where each breathing cycle was divided into ten 0.5 s bins. For both CT and PET acquisitions, patients received audio prompting to regularize breathing. The 4D‐CT and 4D‐PET data were then correlated according to respiratory phase. The effect of 4D acquisition on improving the co‐registration of PET and CT images, reducing motion smearing, and consequently increase the quantitation of the SUV, were investigated. Also, quantitation of the tumor motions in PET, and CT, were studied and compared. 4D‐PET with matching phase 4D‐CTAC showed an improved accuracy in PET‐CT image co‐registration of up to 41%, compared to measurements from 4D‐PET with clinical‐CTAC. Gating PET data in correlation with respiratory motion reduced motion‐induced smearing, thereby decreasing the observed tumor volume, by as much as 43%. 4D‐PET lesions volumes showed a maximum deviation of 19% between clinical CT and phase‐ matched 4D‐CT attenuation corrected PET images. In CT, 4D acquisition resulted in increasing the tumor volume in two patients by up to 79%, and decreasing it in the other two by up to 35%. Consequently, these corrections have yielded an increase in the measured SUV by up to 16% over the clinical measured SUV, and 36% over SUV's measured in 4D‐PET with clinical‐CT Attenuation Correction (CTAC) SUV's. Quantitation of the maximum tumor motion amplitude, using 4D‐PET and 4D‐CT, showed up to 30% discrepancy between the two modalities. We have shown that 4D PET/CT is clinically a feasible method, to correct for respiratory motion artifacts in PET/CT imaging of the thorax. 4D PET/CT acquisition can reduce smearing, improve the accuracy in PET‐CT co‐registration, and increase the measured SUV. This should result in an improved tumor assessment for patients with lung malignancies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
The use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
Self-citationCiernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
Erdi, Y. E., Mawlawi, O., Larson, S. M., Imbriaco, M., Yeung, H., Finn, R., & Humm, J. L. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971215)80:12+<2505::aid-cncr24>3.0.co;2-f · Cited by 480
Self-citationEffect of respiratory gating on quantifying PET images of lung cancer.
Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Schöder, H. M., Larson, S. M., Macapinlac, H. A., Squire, O. D., & Humm, J. L. (2002) · PubMed · Cited by 406
Self-citationPET-CT image co-registration in the thorax: influence of respiration
Goerres, G. W., Kamel, E., Heidelberg, T.-N. H., Schwitter, M. R., Burger, C., & von Schulthess, G. K. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0710-4 · Cited by 332
Beyer, T., Antoch, G., Blodgett, T., Freudenberg, L. F., Akhurst, T., & Mueller, S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1097-6 · Cited by 298
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
Nehmeh, S. A., Erdi, Y. E., Ling, C. C., Rosenzweig, K. E., Squire, O. D., Braban, L. E., Ford, E., Sidhu, K., Mageras, G. S., Larson, S. M., et al. (2002) · Medical Physics · doi:10.1118/1.1448824 · Cited by 297
Self-citationThe CT motion quantitation of lung lesions and its impact on PET-measured SUVs.
Erdi, Y. E., Nehmeh, S. A., Pan, T., Pevsner, A., Rosenzweig, K. E., Mageras, G. S., Yorke, E. D., Schöder, H. M., Hsiao, W., Squire, O. D., et al. (2004) · PubMed · Cited by 282
Self-citationQuantitation of respiratory motion during 4D‐PET/CT acquisition
Nehmeh, S. A., Erdi, Y. E., Pan, T., Yorke, E., Mageras, G. S., Rosenzweig, K. E., Schoder, H., Mostafavi, H., Squire, O., Pevsner, A., et al. (2004) · Medical Physics · doi:10.1118/1.1739671 · Cited by 232
Self-citationCaldwell, C. B., Mah, K., Skinner, M., & Danjoux, C. E. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04609-6 · Cited by 171
Nehmeh, S. A., Erdi, Y. E., Rosenzweig, K. E., Schöder, H. M., Larson, S. M., Squire, O. D., & Humm, J. L. (2003) · PubMed · Cited by 170
Self-citation
Cited by
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
Overview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468
A review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 317
Self-citation
Metadata
- Authors
- Nehmeh, S. A., Erdi, Y. E., Pan, T., Pevsner, A., Rosenzweig, K. E., Yorke, E., Mageras, G. S., Schoder, H., Vernon, P., Squire, O., Mostafavi, H., Larson, S. M., & Humm, J. L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2004-11-08
- Volume
- 31
- Issue
- 12
- Pages
- 3179-3186
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2170076353
- Cited by
- 349
- References
- 14
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.