A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy: Respiratory motion model for use in lung radiotherapy

McClelland, Jamie R., Blackall, Jane M., Tarte, Ségolène, Chandler, Adam C., Hughes, Simon, Ahmad, Shahreen, Landau, David B., Hawkes, David J. · 2006 · Medical Physics

Abstract

Respiratory motion causes errors when planning and delivering radiotherapy treatment to lung cancer patients. To reduce these errors, methods of acquiring and using four-dimensional computed tomography (4DCT) datasets have been developed. We have developed a novel method of constructing computational motion models from 4DCT. The motion models attempt to describe an average respiratory cycle, which reduces the effects of variation between different cycles. They require substantially less memory than a 4DCT dataset, are continuous in space and time, and facilitate automatic target propagation and combining of doses over the respiratory cycle. The motion models are constructed from CT data acquired in cine mode while the patient is free breathing (free breathing CT - FBCT). A "slab" of data is acquired at each couch position, with 3-4 contiguous slabs being acquired per patient. For each slab a sequence of 20 or 30 volumes was acquired over 20 seconds. A respiratory signal is simultaneously recorded in order to calculate the position in the respiratory cycle for each FBCT. Additionally, a high quality reference CT volume is acquired at breath hold. The reference volume is nonrigidly registered to each of the FBCT volumes. A motion model is then constructed for each slab by temporally fitting the nonrigid registration results. The value of each of the registration parameters is related to the position in the respiratory cycle by fitting an approximating B spline to the registration results. As an approximating function is used, and the data is acquired over several respiratory cycles, the function should model an average respiratory cycle. This can then be used to calculate the value of each degree of freedom at any desired position in the respiratory cycle. The resulting nonrigid transformation will deform the reference volume to predict the contents of the slab at the desired position in the respiratory cycle. The slab model predictions are then concatenated to produce a combined prediction over the entire region of interest. We have performed a number of experiments to assess the accuracy of the nonrigid registration results and the motion model predictions. The individual slab models were evaluated by expert visual assessment and the tracking of easily identifiable anatomical points. The combined models were evaluated by calculating the discontinuities between the transformations at the slab boundaries. The experiments were performed on five patients with a total of 18 slabs between them. For the point tracking experiments, the mean distance between where a clinician manually identified a point and where the registration results located the point, the target registration error (TRE), was 1.3 mm. The mean distance between a manually identified point and the models prediction of the point's location, the target model error (TME), was 1.6 mm. The mean discontinuity between model predictions at the slab boundaries, the Continuity Error, was 2.2 mm. The results show that the motion models perform with a level of accuracy comparable to the slice thickness of 1.5 mm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2222079

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 181

Metadata

Authors
McClelland, J. R., Blackall, J. M., Tarte, S., Chandler, A. C., Hughes, S., Ahmad, S., Landau, D. B., & Hawkes, D. J.
Venue
Medical Physics
Publisher
Wiley
Published
2006-08-29
Volume
33
Issue
9
Pages
3348-3358
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2105535692
Cited by
181
References
1
FWCI
14.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy: Respiratory motion model for use in lung radiotherapy. https://app.cochat.ai/papers/10.1118/1.2222079
The paper
McClelland, J. R., Blackall, J. M., Tarte, S., Chandler, A. C., Hughes, S., Ahmad, S., Landau, D. B., & Hawkes, D. J. (2006). A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy: Respiratory motion model for use in lung radiotherapy. Medical Physics. https://doi.org/10.1118/1.2222079

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.